Cisco Catalyst Blade Switch 3120 for HP System Message Guide
2-35
Cisco Catalyst Blade Switch 3120 for HP System Message Guide
OL-12249-01
Chapter 2 Message and Recovery Procedures
GBIC_SECURITY_CRYPT Messages
Error Message GBIC_SECURITY-6-SFP_REMOVED: Transceiver SFP [chars] module removed
from [chars]
Explanation
The online insertion and removal (OIR) facility detected the removal of a transceiver
module from the interface specified in the message. The first [chars] is the module and the second
[chars] is the interface.
Recommended Action No action is required.
GBIC_SECURITY_CRYPT Messages
This section contains the Cisco GBIC, SFP, and 10-Gigabit Ethernet module security messages. The
switch recognizes the module as a Cisco module but identifies another problem with it.
Note The switches support SFP and 10-Gigabit Ethernet modules but do not support GBIC modules. Although
the error message text refers to GBIC interfaces and modules, the messages from the switches actually
refer to the SFP and 10-Gigabit Ethernet module interfaces and modules.
Error Message GBIC_SECURITY_CRYPT-4-ID_MISMATCH: Identification check failed for
GBIC in port [chars]
Explanation
The small form-factor pluggable (SFP) module was identified as a Cisco SFP module,
but the system could not verify its identity. [chars] is the port.
Recommended Action Ensure that the Cisco IOS software running on the switch supports the SFP
module. You might need to upgrade your software. Otherwise, verify that the SFP module was
obtained from Cisco or from a supported vendor.
Error Message GBIC_SECURITY_CRYPT-4-UNRECOGNIZED_VENDOR: GBIC in port [chars]
manufactured by an unrecognized vendor
Explanation The small form-factor pluggable (SFP) module was identified as a Cisco SFP module,
but the switch could not match its manufacturer with one on the known list of Cisco SFP module
vendors. [chars] is the port.
Recommended Action Ensure that the Cisco IOS software running on the switch supports the SFP
module. You might need to upgrade your software.
Error Message GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port [chars] has bad
crc
Explanation
The small form-factor pluggable (SFP) module was identified as a Cisco SFP module,
but it does not have a valid cyclic redundancy check (CRC) in the EEPROM data. [chars] is the port.
Recommended Action Ensure that the Cisco IOS software running on the switch supports the SFP
module. You might need to upgrade your software. Even if the SFP module is unrecognized by the
switch, the SFP module might still operate properly but have limited functionality.