Error Message EC-5-UNSUITABLE: [chars] will not join any port-channel, [chars].
Explanation
One of the interfaces cannot join the EtherChannel because it is configured for PortFast,
as a VLAN Membership Policy Server (VMPS), for IEEE 802.1x, as a voice VLAN, or as a
Switched Port Analyzer (SPAN) destination port. All of these are unsuitable configurations for
EtherChannels. The first [chars] is the interface name, and the second [chars] describes the details
of the unsuitable configuration.
Recommended Action Reconfigure the port; remove the unsuitable configuration.
ETHCNTR Messages
This section contains the Ethernet controller messages. These messages result from a failure of the
switch software when trying to program the hardware and lead to incorrect switch behavior.
Error Message ETHCNTR-3-HALF_DUX_COLLISION_EXCEED_THRESHOLD: Collision at [chars]
exceed threshold. Consider as loop-back.
Explanation The collisions at a half-duplex port exceeded the threshold, and the port is treated as a
loopback. [chars] is the port where the threshold was exceeded.
Recommended Action No action is required. The port goes into error-disabled mode until the problem
is resolved.
Error Message ETHCNTR-3-LOOP_BACK_DETECTED:, Loop-back detected on [chars]. The port
is forced to linkdown.
Explanation
This message occurs when a keepalive packet is looped back to the port that sent the
keepalive. The loopback condition might be caused by a balun cable being accidentally connected
to the port, or there might be a loop in the network. [chars] is the port.
Recommended Action Examine the cables. If a balun cable is connected, and the loopback condition
is desired, no action is required. Otherwise, connect the correct cable, and bring the port up by
entering the no shutdown interface configuration command. We do not recommend using the no
keepalive interface command to disable keepalives. The cause of this network loop must be found
and corrected. Although disabling keepalives prevents the port from being error disabled, it does not
resolve the cause of the problem and can affect network stability. See CSCea46385
for more
information.
Error Message ETHCNTR-3-NO_HARDWARE_RESOURCES: Not enough hardware resources.
Shutting down [chars].
Explanation
There are too many VLANs and routed ports (if the switch supports routed ports)
configured. [chars] is the short interface name, such as Gi0/1, or the VLAN name, such as
VLAN0002.
Recommended Action Reduce the total number of VLANs and routed ports to less than 1023. To
preserve configuration and connections across reboots, save the configuration.