HP StorageWorks Fabric OS 6.1.x administrator guide (5697-0234, November 2009)

Fabric OS 6.1.x administrator guide 255
Supported iSCSI initiators
Checklist for configuring iSCSI
Configure the iSCSI gateway service after you install the FC4-16IP blade in the 4/256 SAN Director. The
following table provides a high-level overview of the commands and links to the sections that detail the
procedures. See the Fabric OS Command Reference for detailed information on the commands.
Table 69 Supported iSCSI initiators
iSCSI initiator driver versions
Windows
MS iSCSI initiator 2.02
MS iSCSI initiator 2.03
MS iSCSI initiator 2.04
Linux
RH EL 4 default initiator
2.6.10 - 4.0.2 iSCSI initiator (SourceForge,Net initiator)
2.4.20 - 3.6.2 iSCSI initiator (SourceForge,Net initiator)
•SUSE 9
•SUSE 10
Solaris
iSCSI is built-in with the 5.11 with the latest Solaris Express release
AIX
iSCSI is built-in in the 5.3 ML4
HP-UX
11i v1 - B.11.23.03e
11 iv2 - B.11.23.03e
NIC/TOE cards
iSCSI HBAs
Alacritech SES2002XT
Qlogic 4050c
Table 70 iSCSI target gateway configuration steps
Step Command Procedure
1 Activate iSCSI for the
FC4-16IP.
fosConfig - -enable iscsi Enabling the iSCSI gateway
service” on page 258
2 Configure the IP address
for GbE port(s).
portCfg ipif <slot>/ge<port>
create <ipaddress> <netmask>
<mtu_size>
Configuring the GbE
interface” on page 259
3 Optional) Configure the
IP route for the GbE
port(s).
portCfg iproute
<slot>/ge<port> args
Configuring the GbE
interface” on page 259
4 (Easy) Automatically
maps FC targets to iSCSI
targets and names
target with unique IQN.
iscsiCfg - -easycreate tgt Automatic iSCSI VT creation
on page 261
5 (Advanced) Create
iSCSI virtual target.
iscsiCfg - -create tgt –t
<targetname>
Manual iSCSI VT creation
on page 263
6Add LUNs to the virtual
target.
iscsiCfg - -add lun -t
<targetname> \
-w <fcwwn> -l
<LUN_map>