HP B-series Fabric OS 7.1.1a Release Notes (5697-3023, November 2013 - includes all 7.1.1x versions)

Table 13 Fabric OS 7.1.1a closed defects (continued)
SolutionClosed defect summary
Fixed in Fabric OS 7.1.1aWebTools does not allow configuration of the "Signal Loss"
area for ports. Users are unable to see signal loss area
stats via WebTools even though they are visible from the
CLI.
Workaround prior to upgrade: Perform a port
disable/enable on the switch ports of the affected devices.
Hosts may not see all target LUNs in a topology using
multi-chassis EX ports on ICL configurations.
Fixed in Fabric OS 7.1.1a
Workaround prior to upgrade: Avoid the agshow CLI
command and manage switches with Network Advisor.
A switch running agshow or polling for AG info from a
Network Advisor seed switch may cause a switch panic
in a fabric with AG switches.
Fixed in Fabric OS 7.1.1a
Workaround prior to upgrade: Keep the port that is
connected to the misbehaving device in disabled state.
Incoming corrupted FLOGI frame may trigger a switch to
panic loop.
Fixed in Fabric OS 7.1.1a
Effective date
November 2013
66