HP B-series Fabric OS 7.1.1a Release Notes (5697-3023, November 2013 - includes all 7.1.1x versions)

Table 13 Fabric OS 7.1.1a closed defects (continued)
SolutionClosed defect summary
Workaround prior to upgrade: Avoid querying an invalid
class from WebTools.
Switches may become unmanageable; unable to process
or accept FOS commands, including a 'Reboot' and the
only way to recover is to power cycle the switch.
Fixed in Fabric OS 7.1.1a
Fixed in Fabric OS 7.1.1aA Switch may fail to send ACK1 to an initial FLOGI from
device that issues FLOGI immediately after the link comes
up.
Workaround prior to upgrade: First disable the FEC/CR
features before downgrading from Fabric OS 7.1.x or
7.2.x to 7.0.x (via the -s option).
Downgrading the standby CP from Fabric OS 7.1.x or
later to 7.0.x leaves FEC enabled on F-port (even though
it is not supported). The firmwaredownload -s
Fixed in Fabric OS 7.1.1a
command executed on Standby CP incorrectly permits the
downgrade from Fabric OS 7.1.x or later to proceed when
FEC is enabled, even though it is not supported by the
downgraded Fabric OS versions (7.0.x or earlier versions).
Fixed in Fabric OS 7.1.1aUnable to delete active ipfilter rule as User Admin and
Root, and mab be unable to access the switch via SSH
and Web until the ipfilter rule is deleted.
Fixed in Fabric OS 7.1.1aThe HP B-series 8/12c BladeSystem SAN Switch and HP
B-series 8/24c BladeSystem SAN Switch display an invalid
message, Request F-N Port Mappings for Access
Gateway Change from SW even though the switch is
in native switch mode. This is a display error only and has
no impact to switch functionality.
Fixed in Fabric OS 7.1.1aThe login database was not properly cleaned up during
CNA failover, on the HP 2408 FCoE Switch or the HP
10/24 FCoE Blade running Fabric OS 6.4.3e and 7.1.1.
Login was aborted and the NPIV devices did not come
online when another login was performed later.
Fixed in Fabric OS 7.1.1aProxy devices may be stuck in an "initializing" state after
domain changes are made, such as adding new switch to
edge fabric.
Fixed in Fabric OS 7.1.1aUsers may experience disruption on a port if that port is
bounced during firmware upgrade from pre-Fabric OS
7.1.0 to 7.1.0 or later.
Fixed in Fabric OS 7.1.1aAn RTWR may occur in the switch for X-late and local
domain after a fabric merge operation.
Fixed in Fabric OS 7.1.1aCertificate import/export is allowed over FTP even in secure
mode, but should not be.
Fixed in Fabric OS 7.1.1aUnable to determine when to tune serdes values for link
optimal performance. The "back end link CRC with good
EOF errors" should be separated from the current ASIC
error monitoring scheme.
Workaround prior to upgrade: Avoid running multiple
supportshow commands from the different sessions.
Kernel panic may occur when running multiple
SupportShow commands in several logical switches.
Fixed in Fabric OS 7.1.1a
Fixed in Fabric OS 7.1.1aMultiple "dump : setting recv version 10" messages and
" "NO MAPS WARNING" are displayed during a
firmware download. These messages are confusing and
should be cleaned up.
Fixed in Fabric OS 7.1.1aThe current default configuration for blade faults is not
sensitive enough for some FICON environment setup.
Customer may experience IFCCs when there are low level
ASIC parity errors.
Fabric OS 7.1.1a fixes 65