HP B-series Fabric OS 7.1.1a Release Notes (5697-3023, November 2013 - includes all 7.1.1x versions)

Table 12 Fabric OS 7.1.1 closed defects (continued)
SolutionClosed defect summary
Adding the Adaptive Networking license key does not
activate the QoS functionality.
Fixed in Fabric OS 7.1.1.Firmware downgrade from Fabric OS 7.1.0 to 7.0.0d is
erroneously blocked when the logical switch does not have
Allow XISL enabled.
Fixed in Fabric OS 7.1.1.A switch Ha Failover or HA Reboot may occur when SNMP
daemon retrieves statistics on an FCIP circuit.
Fixed in Fabric OS 7.1.1.Webtools are unable to enter a D,I zone.
Fixed in Fabric OS 7.1.1.An unstable link caused the switch to internally reset a port,
and generate link level errors.
Fixed in Fabric OS 7.1.1.The weblinkercfgd process may crash when there is a
scheduled SAN Network Advisor backup of the switch.
Fixed in Fabric OS 7.1.1.There is an overall FCIP Tunnel performance degradation
between Fabric OS 7.0.2 and 7.1.0x.
Fixed in Fabric OS 7.1.1.CRC with Good EOF Errors detected on backend ports of
the HP 64-port 8Gb FC Blade when installed in an HP
SN8000B 8-Slot or 4-Slot Director Switches.
Fixed in Fabric OS 7.1.1.The command is not recognized and no error message is
output when attempting to bind a specific 8-bit area to a
port using portaddress --bind <slot>/<port>
<16-bit address> --auto.
Fixed in Fabric OS 7.1.1.Deprecated Fabric OS 7.0 MIBs should be removed
because they are obsolete in Fabric OS 7.1.
Fixed in Fabric OS 7.1.1.EZManager cannot be launched.
Fixed in Fabric OS 7.1.1.A CP panic may occur while taking over the active CP role
leading to a cold recovery on an HP Multi-protocol Router
Blade or an HP Multi-protocol Extension Blade.
Fabric OS 7.1.1a fixes
Table 13 (page 64) lists defects closed in the Fabric OS 7.1.1a firmware release.
Table 13 Fabric OS 7.1.1a closed defects
SolutionClosed defect summary
Fixed in Fabric OS 7.1.1aOn rare occasions excessive writing to an old flash card
may cause it to no longer be accessible during switch
bootup.
Fixed in Fabric OS 7.1.1aSwitches may not be able to be managed from WebTools
or Network Advisor even though management via CLI
works correctly. Under a rare condition management
process (HTTPD) gets stuck and switch reports as
unreachable via Network Advisor and Webtools.
Workaround prior to upgrade: Make sure that there are
only ICL or ISL based egress paths to use when routing
Devices and ingress routes on switches are all routed to
the ISL instead of using any of the ICLs in port based mode,
traffic to any given destination domain, even if the
destination is multiple hops away.
when a customer has both 16 Gb ICL and ISL paths leaving
the current switch (that can all be used for routing to a
remote domain, even if the domain is multiple hops away).
Fixed in Fabric OS 7.1.1a
Fixed in Fabric OS 7.1.1aValues from serdes auto/manual tuning session are lost
after blade power off/power on or switch cold reboot.
64