HP B-series Fabric OS 7.1.1a Release Notes (5697-3023, November 2013 - includes all 7.1.1x versions)
Table 12 Fabric OS 7.1.1 closed defects (continued)
SolutionClosed defect summary
Fixed in Fabric OS 7.1.1.A supportsave initiated by SAN Network Advisor times
out when collecting data.
Fixed in Fabric OS 7.1.1.A switch panic may occur in RTE route module and HA
Failover while at the same time plugging in cables to ISL
ports with one of the trunk port.
Fixed in Fabric OS 7.1.1.Continuous FSS-1001 messages are output after firmware
upgrade from Fabric OS 6.4.2 to 6.4.3c, due to
inconsistent Access Gateway State Synchronization.
Workaround prior to upgrade: Disable all FCIP FICON
Tape Emulation features.
FICON aborts during FCIP read emulation while running
VTS.
Fixed in Fabric OS 7.1.1.
Fixed in Fabric OS 7.1.1.Kernel panic may occur on an HP 2408 FCoE Switch when
continually sending several iterations of the maximum
number of FDISCs.
Fixed in Fabric OS 7.1.1.No bottleneck alert is generated, even if frames are already
being discarded due to a timeout.
Fixed in Fabric OS 7.1.1.The HP SAN Encryption Switch went into low memory state
because of Continuous polling from SAN Network
Advisor.
Fixed in Fabric OS 7.1.1.The QSFP LED state is inconsistent with the port state on
the four channels (ports).
Fixed in Fabric OS 7.1.1.A configuration download failure occurs when
downloading fabric watch settings.
Fixed in Fabric OS 7.1.1.The HP 1606 SAN Extension Switch tunnel goes into a
DwnPend state after making a change to a committed rate.
Fixed in Fabric OS 7.1.1.ASIC entries are not being cleared during HA Failover
processing on an HP SN8000B 8-Slot or 4-Slot Director,
which leads to server issues.
Fixed in Fabric OS 7.1.1.When ICL Port Fencing is enabled, Web Tools displays
incorrect options for port enable/disable.
Fixed in Fabric OS 7.1.1.In a heavily congested fabric, if an HA Failover occurs
during backend port reporting timeout frame, the switch
falsely identifies a stuck VC and performs a link reset.
Fixed in Fabric OS 7.1.1.D-Port test between AG and the HBA may get stuck in an
IN PROGRESS status.
Fixed in Fabric OS 7.1.1.Access Gateway does not respond to an FLOGI from the
host.
Workaround prior to upgrade: Disable auto tuning.After enabling auto tuning, HP 64-port 8Gb FC Blades
faulted in a 16 Gb chassis.
Fixed in Fabric OS 7.1.1.
Fixed in Fabric OS 7.1.1.The SAN Network Advisor fails to get VF details for the
switch when FMS mode is enabled.
Workaround prior to upgrade: Disable FCIP and all FICON
emulation on a tunnel.
Director switches may experience a panic with the
termination of the fabricd process.
Fixed in Fabric OS 7.1.1.
Fixed in Fabric OS 7.1.1.Removing the Adaptive Networking license key does not
remove the QoS functionality until the link is dropped.
Fabric OS 7.1.1 fixes 63