Table 12 Fabric OS 7.1.1 closed defects (continued)
SolutionClosed defect summary
Fixed in Fabric OS 7.1.1.Misleading (DPort + DWDM) instructions to "enable the
port" to remove DWDM upon proper firmwaredownload
failure.
Fixed in Fabric OS 7.1.1.The command IpAddrSet --delete is unsuccessful at
removing an IPv6 switch address.
Fixed in Fabric OS 7.1.1.Serdes values for an HP 16-port 8Gb FC Blade in slot 1,2
of an HP DC SAN Backbone Director need to be updated.
Fixed in Fabric OS 7.1.1.Power supply reports faulty (EM-1034) message on
alternate power supplies in HP StoreFabric SN6500B FC
Switches.
Workaround prior to upgrade: Disable Open Systems Tape
Pipelining.
TSM experiencing errors when OXID re-use is encountered
and operation is dropped on PI side when FCIP OSTP is
enabled.
Fixed in Fabric OS 7.1.1.
Workaround prior to upgrade: Disable jumbo frame
support in an IP connected infrastructure when the HP 1606
The HP 1606 SAN Extension Switch/HP Multiprotocol
Extension Blade may experience DP panics when Ethernet
jumbo frames are forwarded to the CP. SAN Extension Switch/HP Multiprotocol Extension Blade
are connected.
Fixed in Fabric OS 7.1.1.
Fixed in Fabric OS 7.1.1.An incorrect route is removed when switching TIzone from
failover-enabled to failover-disabled.
Fixed in Fabric OS 7.1.1.A switch could panic if FC and DCE blades are removed
or powered down during HA Failover.
Workaround prior to upgrade: Rebooting the HP Encryption
Switch or the HP Encryption Blade may alleviate this
problem.
SAN Network Advisor may experience an out of memory
error when obtaining or polling for encrypted LUN level
info from two encryption groups that each have 4,000
defined LUNs.
Fixed in Fabric OS 7.1.1.
Fixed in Fabric OS 7.1.1.If FEC is enabled, the deskew value of the last online port
of the trunk group may show a difference of up to 36.
Fixed in Fabric OS 7.1.1.Firmwaredownload may fail with the message missing
or invalid firmware signature.
Fixed in Fabric OS 7.1.1.A 16 Gb switch may panic when an ICL port enters the
soft fault state.
Fixed in Fabric OS 7.1.1.Stale socket connections may cause key retrieval failure
on the HP SAN encryption switch.
Fixed in Fabric OS 7.1.1.When transferring a CSR using IPv6, the status message
reports a failure even though it actually succeeded.
Fixed in Fabric OS 7.1.1.Values from SerDes auto/manual tuning are lost after
poweroff/poweron of a blade or cold reboot of switch.
Workaround prior to upgrade: Disable FCIP Open Systems
Tape Pipelining.
With OSTP enabled, third-party device write errors are
encountered during backup processing.
Fixed in Fabric OS 7.1.1.
Workaround prior to upgrade: Disable the system card
feature from the encryption group leader by executing the
System security card is not being read on HP SAN
Encryption Switch/HP Encryption Blade card readers.
command: cryptocfg -- set -systemcard
disable.
Fixed in Fabric OS 7.1.1.
62