HP B-series Fabric OS 7.1.1a Release Notes (5697-3023, November 2013 - includes all 7.1.1x versions)
Table 12 Fabric OS 7.1.1 closed defects (continued)
SolutionClosed defect summary
crash and switch reboot when managed by SAN Network
Advisor.
connected to either N_Port or F_Port or have AG in auto
policy disabled state.
Fixed in Fabric OS 7.1.1.
Fixed in Fabric OS 7.1.1.Unable to delete user account in VF environment created
using AD settings.
Fixed in Fabric OS 7.1.1.Diagshow command in interactive mode hangs and leads
to high CPU utilization when Telnet session is killed.
Workaround prior to upgrade: Bounce the port by
performing a portdisable and portenable.
Fibre Channel loop even is not completed when disk is
removed from Loop storage connected to an HP 8/8 SAN
Switch or an HP 8/24 SAN Switch.
Fixed in Fabric OS 7.1.1.
Fixed in Fabric OS 7.1.1.Switch mib browser displays misinterpreted fcportflag.
Workaround prior to upgrade: Disable FCIP Open Systems
Tape Pipelining.
Restore job failing after partial restore.
Fixed in Fabric OS 7.1.1.
Fixed in Fabric OS 7.1.1.BRCD-FCIP-Ext MIB does not function as documented in the
MIB reference.
Fixed in Fabric OS 7.1.1.Standby CP panics every time two port blades are moved
into a new logical switch.
Fixed in Fabric OS 7.1.1.An HP 64-port 8Gb FC Blade installed in an HP SN8000B
8-Slot SAN Backbone Director or an HP SN8000B 4-Slot
Backbone director Switch incorrectly faults during POST
after a power cycle.
Workaround prior to upgrade: Remove the misconfigured
DCC policy and use the fabric.
Setting strict mode with DCC policy from disabled switch
can cause dual CP panic.
Fixed in Fabric OS 7.1.1.
Fixed in Fabric OS 7.1.1.CP Faulty reason is not persistent over a reboot.
Fixed in Fabric OS 7.1.1.For all 16Gb switch platforms and HP SN8000B 8Gb
32-port and 48-port Enhanced Fibre Channel Blades, an
error message is shown when the Web Tools port admin
wizard is used to configure long distance with VC_Link
INIT set to Arbitrary(1).
Fixed in Fabric OS 7.1.1.The HP SN8000B 8-Slot SAN Backbone Director goes into
a reboot loop with POST failing for all 16Gb blades where
the default FID of the default switch was changed to
something other than 128.
Fixed in Fabric OS 7.1.1.Logical Fabric Addressing Modes are unexpectedly
modified.
Workaround prior to upgrade: Disable FCIP Fastwrite and
Tape Pipelining.
The HP 1606 SAN Extension Switch panics when the host
writes data to a tape drive via the FCIP tunnel with fastwrite
and tape pipelining enabled.
Fixed in Fabric OS 7.1.1.
Fixed in Fabric OS 7.1.1.Remote mirroring is not working when fastwrite is enabled.
Fixed in Fabric OS 7.1.1.HTTP status queried from SAN Network Advisor returned
as failed even though firmwaredownload finished
successfully in the device.
Workaround prior to upgrade: Reboot the HP Encryption
SAN Switch or the HP Encryption Blade.
Continuous decrease in free memory on blade processor
when polling container stat every 30 seconds.
60