HP B-series Fabric OS 7.1.1a Release Notes (5697-3023, November 2013 - includes all 7.1.1x versions)

Table 12 Fabric OS 7.1.1 closed defects
SolutionClosed defect summary
Fixed in Fabric OS 7.1.1.Spinfab does not attain saturation of 3.2G throughput over
long distance E_Port due to reduced size frames.
Fixed in Fabric OS 7.1.1.When set timebase option for class SFP, area PWRONHRS
to none, the following error occurs: Timebase not
supported by this class.
Fixed in Fabric OS 7.1.1.CRC with Good EOF Errors detected in Slot 1 port 2 of HP
DC04 SAN Director Switch with an HP 48-port 8Gb FC
Blade installed in Slot 1 of the director.
Fixed in Fabric OS 7.1.1.The ipfilter --show command continues to display
RPC ports.
Fixed in Fabric OS 7.1.1.CRC with Good EOF Errors detected in slot 3 on ports
3/42 <-> 8/139 of an HP DC SAN Backbone Director
Switch with an HP 48-port 8Gb FC Blade installed.
Fixed in Fabric OS 7.1.1.HTTP TRACE requests are processed over HTTPS/SSL
connections.
Fixed in Fabric OS 7.1.1.On an HP DC04 SAN Director Switch, backend CRC errors
detected on core blade port 3/56 connecting HP 32-port
8Gb FC Blade.
Fixed in Fabric OS 7.1.1.When an access control list is configured for SNMP and
the list contains a subnet area, that particular subnet is not
able to query the switch.
Fixed in Fabric OS 7.1.1.Unstable ICL/BI ports may cause a switch reboot. This
could affect the HP DC SAN Backbone Director switch or
the HP Multiprotocol Extension Blade.
Fixed in Fabric OS 7.1.1.A race condition during an SNMP query of interface
statistics caused a switch panic on the HP 2408 FCoE
Switch.
Fixed in Fabric OS 7.1.1.FabricWatch trap 5 is not being sent to 3rd party tool
when running Fabric OS 7.0.1.
Fixed in Fabric OS 7.1.1.After setting a low threshold for SFP temperature on an HP
SN3000B 16Gb FC Switch, the temperature is shown as
above instead of below.
Fixed in Fabric OS 7.1.1.There is inconsistent output from turboramtest on HP
SN8000B SAN Director Switches and the HP SN6000B
16Gb FC Switch.
Fixed in Fabric OS 7.1.1.Unable to upgrade FPGA image separately from Fabric
OS on HP Encryption Blade and HP Encryption SAN
Switch.
Fixed in Fabric OS 7.1.1.When running full bandwidth bi-directional traffic in a
recommended 16Gb ICL topology configuration, some
traffic flows may experience performance throughput
degradation.
Workaround prior to upgrade: Perform a cold reboot.After diag test, switch route table (RTE) is not being updated
properly.
Fixed in Fabric OS 7.1.1.
Fixed in Fabric OS 7.1.1.Name Server loses FC4 type in routed environment.
Fixed in Fabric OS 7.1.1.The HP 8/40 SAN Switch does not transmit SNMP trap
as chassis instance after user configured sysmonitor.
Workaround prior to upgrade: Avoid managing the AG
switch from SAN Network Advisor or have all ports
The HP B-series 8/12c BladeSystem SAN Switch and the
HP B-series 8/24c BladeSystem SAN Switch exhibit snmpd
Fabric OS 7.1.1 fixes 59