HP B-series Fabric OS 7.1.1a Release Notes (5697-3023, November 2013 - includes all 7.1.1x versions)
Table 11 Fabric OS 7.1.0b closed defects (continued)
SolutionClosed defect summary
Workaround prior to upgrade: Disable FCIP Open Systems
Tape Pipelining.
After a partial restore, a tape job fails and the host receives
an incorrect block causing the entire job to terminate.
Fixed in Fabric OS 7.1.0b.
Workaround prior to upgrade: Use the switch admin
extended fabric panel.
For all 16 Gb platforms and the HP SN8000B 8Gb 32-port
and 48-port Enhanced Fibre Channel Blades, an error
Fixed in Fabric OS 7.1.0b.
message displays in the Web Tools port admin wizard
when it is used to configure long distance with VC_Link
INIT set to Arbitrary(1).
Fixed in Fabric OS 7.1.0b.After a physical power failure, the HP SN8000B 8-Slot
SAN Backbone Director Switch experienced a reboot loop
with POST failing for all 16 Gb blades, where the default
FID of the default switch was changed to something other
than 128.
Workaround prior to upgrade: Disable FCIP Fastwrite and
tape pipelining.
The HP 1606 SAN Extension Switch panics when the host
writes data to a tape drive via an FCIP tunnel with fastwrite
and tape pipelining enabled.
Fixed in Fabric OS 7.1.0b.
Workaround prior to upgrade: Disable FCIP Fastwrite on
the tunnel.
Remote mirroring is not working and replication may fail
when fastwrite is enabled.
Fixed in Fabric OS 7.1.0b.
Fixed in Fabric OS 7.1.0b.There is a continuous decrease in free memory on blade
processors when polling the container stat every 30
seconds.
Workaround prior to upgrade: Disable FCIP Open Systems
Tape Pipelining.
The HP DC SAN Director Multiprotocol Extension Blade
DP panics, FCIP tunnels go down and become unavailable
when FCIP tape pipelining is enabled.
Fixed in Fabric OS 7.1.0b.
Workaround prior to upgrade: Disable FCIP FICON Tape
Pipelining or XRC emulation.
A negative value is displayed for the number of FICON
Host side paths in the command display.
Fixed in Fabric OS 7.1.0b.
Workaround prior to upgrade: Disable and enable the
invalid port.
On trunk master EX_Port disable, all the parameters from
the old master port are erroneously copied the neighbor
pwwn.
Fixed in Fabric OS 7.1.0b.
Workaround prior to upgrade: Disable open systems tape
pipelining or limit tunnel vtn to 1.
TSM fails on writes to LTO5 drives when appending.
Fixed in Fabric OS 7.1.0b.
Fixed in Fabric OS 7.1.0b.XTUN-1007 errors are logged during system verification
tests on an HP DC SAN Backbone Director / HP SN8000B
8-Slot SAN Backbone Director with an HP DC SAN Director
Multiprotocol Extension Blade installed.
Workaround prior to upgrade: Issue the following
command sequence to properly recover from the error:
Misleading (DPort + DWDM) instructions to enable the port
to remove DWDM upon firmwaredownload failure.
portdisable <port>
portCfgDport --disable <port>
portenable <port>
Although the firmware download is correctly blocked, the
instructions are misleading and do not help rectify the
situation.
Fixed in Fabric OS 7.1.0b.
Fixed in Fabric OS 7.1.0b.Power supply reports faulty (EM-1034) message on
alternate power supplies in the HP StoreFabric SN6500B
16Gb FC Switch.
Fabric OS 7.1.0b fixes 57