HP B-series Fabric OS 7.1.1a Release Notes (5697-3023, November 2013 - includes all 7.1.1x versions)
Table 9 Fabric OS 7.1.0 closed defects (continued)
SolutionClosed defect summary
Fixed in Fabric OS 7.1.0.When a non-decryptable DF mode tape is processed by
the encryption switch, it can cause a
DECRYPT_DECOMPRESS timeout/failure, which in some
instances can cause other tape jobs to fail. In the most
serious case, the HP Encryption SAN switch or the HP DC
Switch Encryption FC Blade will fault, aborting all tape
jobs.
Fixed in Fabric OS 7.1.0.A WWN mapped to a port group from Web Tools is being
mapped to a port. An erroneous information message is
displayed while mapping a WWN to a port group after
removing the WWN's primary and secondary mapping.
Fixed in Fabric OS 7.1.0.Users will not see the correct WWN when rLIRFabricWwn
is queried through SNMP.
Fixed in Fabric OS 7.1.0.The ipfilter counters do not account for IPv6 statistics:
ipfilter –showcounters displays the bandwidth
statistics for IPv4 but not for IPv6 and ipfilter
–clrcounters clears statistics for IPv4 but not for IPv6.
Fixed in Fabric OS 7.1.0.Wildcard-matched ports inconsistent with manually-allowed
ports for DCC policies. For example, if the
secpolicycreate command with a range is executed
in a switch having a broken port range (such as 16-21,
48-63) policies will be created for all the port numbers,
including the missing ports.
Fixed in Fabric OS 7.1.0.ACL policy is ignored with HBA hardware-based trunking.
Fixed in Fabric OS 7.1.0.The nsinfo.html for the switch may not be updated
with devices that have been removed from an LSAN zone.
Fixed in Fabric OS 7.1.0.An SNMP Internal SCN reports a queue full message
“MQ-100”5 from the HP 4/256 SAN Director running
FOS v6.4.0c1.
Fixed in Fabric OS 7.1.0.The passwddefault and distribute do not remove the
associated authorized_keys file.
Fixed in Fabric OS 7.1.0.User may see a RASLOG about failover when an N-Port
that is not the N-Port for the configured F-Ports is enabled.
However, no failover actually occurs.
Fixed in Fabric OS 7.1.0.A TPERF session may not be able to be restarted until all
user-disabled GE ports on the test tunnel are re-enabled.
Fixed in Fabric OS 7.1.0.The LUN State may be shown as "Re-key pending (Unable
to start because of critical error)" after replacing an HA
member + failover.
Fixed in Fabric OS 7.1.0.There is a potential inability for FICON channels to
successfully establish logical paths to the CUP in
configurations where there is a large number of
sub-channels defined to the CUP.
Fixed in Fabric OS 7.1.0.Ports without errors are fenced during supportsave.
Fixed in Fabric OS 7.1.0.Infrequently, LUN discovery failure may be encountered
after HAC failback for certain tape devices.
Fixed in Fabric OS 7.1.0.In a FICON environment (without CUP) inconsistent
switchshow output displays on Port #254 and #255 as
port 254 is showing "Disabled (FMS Mode)" and port 255
is showing "Disabled (Persistent) (FMS Mode)”.