HP B-series Fabric OS 7.1.0_blv Release Notes (5697-2827, September 2013)

Table 4 Fabric OS 7.1.0b closed defects (continued)
SolutionClosed defect summary
Workaround prior to upgrade: Disable and enable the
invalid port.
On trunk master EX_Port disable, all the parameters from
the old master port are erroneously copied the neighbor
pwwn.
Fixed in Fabric OS 7.1.0b.
Workaround prior to upgrade: Disable open systems tape
pipelining or limit tunnel vtn to 1.
TSM fails on writes to LTO5 drives when appending.
Fixed in Fabric OS 7.1.0b.
Fixed in Fabric OS 7.1.0b.XTUN-1007 errors are logged during system verification
tests on an HP DC SAN Backbone Director / HP SN8000B
8-Slot SAN Backbone Director with an HP DC SAN Director
Multiprotocol Extension Blade installed.
Workaround prior to upgrade: Issue the following
command sequence to properly recover from the error:
Misleading (DPort + DWDM) instructions to enable the port
to remove DWDM upon firmwaredownload failure.
portdisable <port>
portCfgDport --disable <port>
portenable <port>
Although the firmware download is correctly blocked, the
instructions are misleading and do not help rectify the
situation.
Fixed in Fabric OS 7.1.0b.
Fixed in Fabric OS 7.1.0b.Power supply reports faulty (EM-1034) message on
alternate power supplies in the HP StoreFabric SN6500B
16Gb FC Switch.
Workaround prior to upgrade: Disable FCIP Open Systems
Tape Pipelining.
TSM experiences errors when OXID re-use is encountered
and the operation is dropped on the PI side when FCIP
OSTP is enabled.
Fixed in Fabric OS 7.1.0b.
Workaround prior to upgrade: Disable jumbo frame
support in IP connected infrastructure where an HP 1606
The HP 1606 SAN Extension Switch and HP DC SAN
Director Multiprotocol Extension Blade DP panic when
Ethernet jumbo frames are forwarded to the CP. SAN Extension Switch or HP DC SAN Director
Multiprotocol Extension Blade are connected.
Fixed in Fabric OS 7.1.0b.
Fixed in Fabric OS 7.1.0b.Network Advisor experiences an out of memory error when
obtaining or polling for encrypted LUN level info from two
encryption groups that each have 4,000 defined LUNs.
Fixed in Fabric OS 7.1.0b.If FEC is enabled, the deskew value of the last online port
of the trunk group may show a difference of up to 36.
Workaround prior to upgrade: Retry the
firmwaredownload using ftp. Verify that the standby CP
ethernet cable is properly plugged in.
The firmwaredownload failed due to a missing or invalid
firmware signature.
Fixed in Fabric OS 7.1.0b.
Fixed in Fabric OS 7.1.0b.A 16 Gb switch may panic when an ICL port enters soft
fault state. This is very unlikely but may also occur with
backend internal or backend xxternal ports.
Workaround prior to upgrade: Disable FCIP Open Systems
Tape Pipelining.
With OSTP enabled, TSM write errors are encountered
during backup processing.
Fixed in Fabric OS 7.1.0b.
Workaround prior to upgrade: Disable the systemcard
feature, issue cryptocfg -- set -systemcard
disable from the encryption group leader.
The system security card is not being read on an HP
Encryption SAN Switch / HP DC Switch Encryption FC
Blade card readers.
Fixed in Fabric OS 7.1.0b.
Fixed in Fabric OS 7.1.0b.Network Advisor initiated supportsave times out when
collecting data.
38