HP B-series Fabric OS 7.1.0_blv Release Notes (5697-2827, September 2013)

Table 2 Fabric OS 7.1.0 closed defects (continued)
SolutionClosed defect summary
Workaround prior to upgrade:Open Systems Tape Read job failures occur while running
multiple tapes.
Disable FCIP tape read pipelining.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.Fabric OS/HP Encryption SAN Switch/Network Advisor
allow encryption container creation in the absence of a
related L2 zone.
Fixed in Fabric OS 7.1.0.Loop port comes up "In_Sync" after a port bounce.
Fixed in Fabric OS 7.1.0.The Brocade BR5470 will only negotiate to 4Gb.
Fixed in Fabric OS 7.1.0.There is inappropriate information in swSensorValue MIB
after switching off the power supply on an HP SN6000B
16Gb FC Switch.
Fixed in Fabric OS 7.1.0.Webtools SwitchView shows details for ports in other FIDs.
Fixed in Fabric OS 7.1.0.The perfresourceshow --installed command
output is inconsistent with the documentation.
Workaround prior to upgrade:A kernel panic occurs during upgrade to Fabric OS 6.4.3
and 7.0.1b or later.
Avoid any discovery frames during
HA/firmware-download.
Fixed in Fabric OS 7.1.0.
Workaround prior to upgrade:An abort received from the Channel immediately after
starting FICON Tape Read Pipelining.
Disable FCIP FICON tape read pipelining.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.Boot over SAN may have an 8 second delay when the
target device is not on the local switch.
Workaround prior to upgrade:The HTTPD (Apache server 1.3.31-10) goes to a defunct
state, causing loss of manageability by Network Advisor.
Restart the httpd or perform an Ha Failover.
Fixed in Fabric OS 7.1.0.
Workaround prior to upgrade:FICON IFCCs for extended Emulated Printer sequences
during Unit Check Processing.
Disable FICON printer emulation.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.CRC with Good EOF errors detected on the HP DC SAN
Backbone Director on 5/139 link when an HP SAN
Director 32-port 8Gb FC Blade is installed in slot 3 and
on 5/100 link when an HP DC SAN Director Multiprotocol
Extension Blade is installed in slots 4.
Workaround prior to upgrade:“HTTP error:: Fatal connection error” is displayed when
changing the port configuration policy while in AG mode.
Use the AG CLI to configure the AG port policy.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.EE monitors in VF environments with duplicate PID/SID on
the same ASIC do not function properly.
Workaround prior to upgrade:On the HP 8/8 SAN Switch, HP 8/24 SAN Switch, and
the HP 8/80 SAN Switch the Hardware tool shows the
Run portdisable CLI on ports without POD licenses.
SerDes are still on and generating signals on ports without
a POD license, causing an EMI issue.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.A director switch became non-responsive from all access
methods with a possible CPU overload.
32