HP B-series Fabric OS 7.1.0_blv Release Notes (5697-2827, September 2013)

Table 2 Fabric OS 7.1.0 closed defects (continued)
SolutionClosed defect summary
Fixed in Fabric OS 7.1.0.The fmmonitor create command returns an undefined
error code when trying to create the 42nd monitor rather
than returning "Maximum no of monitors reached”.
Fixed in Fabric OS 7.1.0.The discard C3 counter does not match the sum of the
registers it represents.
Fixed in Fabric OS 7.1.0.The thconfig --show filter command shows that
there are 51areas, (9defaults, 41user-defined, and 1
perfPT), even though the max frame_type is 50.
Fixed in Fabric OS 7.1.0.Interface flowcontrol change modifies the running config,
but the interface stats do not show the change.
Fixed in Fabric OS 7.1.0.On encryption platforms, a high frequency of Test Unit
Ready (TUR) etc., commands result in DataBase out of sync.
Fixed in Fabric OS 7.1.0.The perfttmon --show [number of flows]
command does not show expected results.
Fixed in Fabric OS 7.1.0.The Brocade 5640 switch posts hundreds of LF and LOS
during firmware download and power on.
Fixed in Fabric OS 7.1.0.When configuring a user monitor with multiple offsets and
each offset has multiple values in the value list, the counts
are inaccurate.
Fixed in Fabric OS 7.1.0.The SFID and DFID fields in the output of Frame Viewer
(using framelog --show) may be incorrect.
Workaround prior to upgrade:Frame drops are encountered on 8 Gb/s platforms when
credit loss is detected.
Reseat the blade.
Fixed in Fabric OS 7.1.0.
Workaround prior to upgrade:With FCIP fast write enabled, the PI sends the incorrect
RXID after a check condition.
Disable FCIP Fast Write.
Fixed in Fabric OS 7.1.0.
Workaround prior to upgrade:I/O failures to Open Systems Tape Device occur on FCIP
Tunnel with FCIP fast write enabled.
Disable FCIP Fast Write.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.POST timeout takes over 60 seconds to complete on a
Brocade 5460.
Workaround prior to upgrade:FCIP OSTP encounters "File too large" errors when running
to a new tape device.
Disable FCIP OSTP Emulation or limit tunnel bandwidth to
less than 5 Gb/s with fewer than 5 FCIP Circuits.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.Switch experiences a panic during firmware download
and CPs lose HA Sync.
Fixed in Fabric OS 7.1.0.Monitor software cannot trigger on INFO message and
the severity level of the FSSM-1004 Info message is
upgraded to Warning.
Workaround prior to upgrade:OXID is being reused on the target side in fast write tape
pipelining and is causing failures.
Disable FCIP Open Systems tape pipelining.
Fixed in Fabric OS 7.1.0.
Fabric OS 7.1.0 fixes 31