HP B-series Fabric OS 7.1.0_blv Release Notes (5697-2827, September 2013)
Table 2 Fabric OS 7.1.0 closed defects (continued)
SolutionClosed defect summary
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.Soft parity errors are causing disruption on the HP
Encryption SAN switch and the HP DC Switch Encryption
FC Blade.
Fixed in Fabric OS 7.1.0.Target device operating at 8 Gb/s fails to gain connectivity
to the HP SN8000B SAN Directors.
Fixed in Fabric OS 7.1.0.Results of a slotshow command reports a software faulted
CP as enabled despite being halted as a result of rebooting
five times.
Fixed in Fabric OS 7.1.0.The Webtools throughput utilization graph does not match
portperfshow output.
Fixed in Fabric OS 7.1.0.There is a large number of CRC with good EOF errors on
the HP DC SAN Backbone Directors when an HP DC SAN
Director 64-port 8Gb FC Blade is installed in slots 1,3,9.
Workaround prior to upgrade:The PortPerfShow command is showing bandwidth
utilization being reported as 0.
Perform an HA Failover.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.Some SNMP MIBs such as swCpuAction and swMemAction
are not accurate.
Fixed in Fabric OS 7.1.0.The LED behavior of HP SN3000B 16Gb FC Switch FAN
FRU does not match what is documented in the hardware
manual.
Fixed in Fabric OS 7.1.0.The fmmonitor --clear command does not properly
clear the Count value.
Fixed in Fabric OS 7.1.0.The IP address is not included in agshow on a switch in
AG mode using IPv6.
Fixed in Fabric OS 7.1.0.The weblinker file descriptor on the CEE platform leaks
when monitored by Network Advisor.
Fixed in Fabric OS 7.1.0.Selected switch configurations are accessible without
authenticating.
Fixed in Fabric OS 7.1.0.The HP DC SAN Director Multiprotocol Extension Blade
DP 1 Soft Faults due to DP Panic.
Fixed in Fabric OS 7.1.0.The HP DC SAN Backbone Director root file system may
be exported during a security scan using "nessus" auditing
software.
Fixed in Fabric OS 7.1.0.Disk replication fails when response to RNID is discarded.
Fixed in Fabric OS 7.1.0.Unable to remove the fmmonitor that has been added to
port 0 with the default Frame Type (SCSI).
Fixed in Fabric OS 7.1.0.When there is a race condition between the fabric watch
and environment monitor modules during bootup, fabric
watch could get stale information and falsely identify a
power supply that is not there.
Workaround prior to upgrade:With In Order Delivery set, using port mirroring to view
traffic causes the switch traffic to stop.
HA Failover will resume traffic.
Fixed in Fabric OS 7.1.0.