HP B-series Fabric OS 7.1.0_blv Release Notes (5697-2827, September 2013)
Table 2 Fabric OS 7.1.0 closed defects (continued)
SolutionClosed defect summary
Workaround prior to upgrade:When users perform portloopbacktest repeatedly
on the HP 8/80 SAN Switch running Fabric OS
Avoid running portloopbacktest in loop.
7.0.1/7.01a in a loop script, even though the repeated
Fixed in Fabric OS 7.1.0.
tests complete with a "PASSED", the switch moves to a
faulty status.
Workaround prior to upgrade:The Onboard Administrator incorrectly reports the
management IP address for the Brocade 8Gb SAN Switch
Reboot the switch after the firmware download.
for HP BladeSystem c-Class when using DHCP. It is shown
as 0.0.3.0 after upgrading to Fabric OS 6.4.0 and later.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.Users may notice slow performance when running a script
with many commands. However, individual command
response time is still within seconds.
Workaround prior to upgrade:The HP SN8000B SAN Directors standby CP panics after
running system verification when they are fully populated
with HP DC SAN Director 64-port 8Gb FC Blades.
Remove one of the HP DC SAN Director 64-port 8Gb FC
Blades for system verification to pass without any issue.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.FICON Emulation incorrectly generates LBY in response to
an unsolicited status from an alias device.
Fixed in Fabric OS 7.1.0.There is a slow response to VLAN requests from the CNA
on an HP 2408 FCoE Converged Network Switch.
Fixed in Fabric OS 7.1.0.Various man pages are lacking specific details.
Fixed in Fabric OS 7.1.0.Several FICON IFCCs are reported during initial online
processing.
Fixed in Fabric OS 7.1.0.Non-FC ports do not support media validated against OUI.
Workaround prior to upgrade:The show process cpu summary output does not match the
current cpu utilization or load.
Top and upload at the Fabric OS interface shows the
proper data.
Fixed in Fabric OS 7.1.0.
Workaround prior to upgrade:SFP shows "No Module" on switches during a failover test
when connected through DWDM.
Disable and re-enable the ports.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.Performance issues occur on a compressed FCIP tunnel
when running Fabric OS 7.0.1a compared to Fabric OS
6.4.2.
Fixed in Fabric OS 7.1.0.Man pages for islshow and fdmishow are inconsistent
with intended functionality.
Fixed in Fabric OS 7.1.0.Port Fencing raslog message FW- 1202 FW-1501 severity
needs to be upgraded from Warning to Error.
Fixed in Fabric OS 7.1.0.SW-MIB files do not load into the MIB Browser because a
tab is being used instead of a space.
Fixed in Fabric OS 7.1.0.Performing switchdisable, configdefault,
portcfgpersistenetenable, portcfgdefault,
then portcfgpersistent enable can cause some
ports to stay in "FC Disabled" state.
Workaround prior to upgrade:When issuing the statsclear command it will return
the error that slot0 is non-existent in Fabric OS 7.0.1a.
Use the slotstatsclear command instead of
statsclear.
Fabric OS 7.1.0 fixes 29