HP B-series Fabric OS 7.1.0_blv Release Notes (5697-2827, September 2013)
Table 2 Fabric OS 7.1.0 closed defects (continued)
SolutionClosed defect summary
Fixed in Fabric OS 7.1.0.The seccertutil command fails to download certificates
from an ftp server if the password ends with an exclamation
mark (!).
Workaround prior to upgrade:Performing an upgrade on an HP DC SAN Backbone
Director from Fabric OS 6.4.1a to 6.4.2b results in many
ports at "Not ready for F or L ports".
Manually rebuild fabric by bouncing the E_port or perform
a switch disble/enable.
Fixed in Fabric OS 7.1.0.
Workaround prior to upgrade:The HP DC SAN Backbone Director with an HP
StorageWorks DC Switch Encryption FC Blade reports FSS
Reboot the standby CP.
error in the RAS log after a cryptocfg --commit
command.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.A switch panic occurs when users enter an index range
with a larger value than is present using the portname
-i -f command.
Fixed in Fabric OS 7.1.0.WebTools are considered an untrusted application.
Fixed in Fabric OS 7.1.0.FICON emulation is not handling IU pacing updates
properly. Aborts occur on the fabric with an HP
StorageWorks 400 Multi-protocol Router and the
application fails.
Fixed in Fabric OS 7.1.0.In Fabric OS 7.0 and later, a name server request "RFT_ID"
for several NPIV ports are rejected with reason 0x05
(Logical Busy) and the host cannot see the device if it does
not retry the request.
Fixed in Fabric OS 7.1.0.On HP SN6000B 16Gb FC Switch, the portledtest
-action option does not display the LED pattern
documented in the help page.
Workaround prior to upgrade:The device is not failing over to its alternate port if that
alternate port happens to be on the upper part of the HP
Use port indexes 239-254.
StorageWorks DC SAN Director 64-port 8Gb FC Blade
such as port indexes 868 to 884.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.Ports LEDs do not flash on 16Gb/s switches during the
portloopback.
Fixed in Fabric OS 7.1.0.Unable to create a CSR file using the command
seccertutil when IPV6 is configured.
Fixed in Fabric OS 7.1.0.A failure occurs when running 'portledtest -npass 10',
'portloopbacktest -lb_mode 1' test.
Fixed in Fabric OS 7.1.0.SNMP crashes while generating core files and then fails
to restart.
Workaround prior to upgrade:The userconfig --change command on the HP
SN8000B SAN Directors running Fabric OS 7.0.1 displays
glibc detected, invalid pointer error.
Manually delete and recreate the user via CLI.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.WebTools function logged in using the User profile displays
the CSCTL option as bold and is functional, but the
dropdown list does not show any bolded options.
Workaround prior to upgrade:FCIP Emulation does not release aborted exchanges,
potentially causing generated SCSI Busy status sequences
if the exchange is reused within 22 seconds.
Disable the FCIP emulation.
Fixed in Fabric OS 7.1.0.
28