HP B-series Fabric OS 7.1.0_blv Release Notes (5697-2827, September 2013)

Table 2 Fabric OS 7.1.0 closed defects (continued)
SolutionClosed defect summary
The issues are linked with Good EOF CRC errors associated
with SERDES tuning for HP DC Switch Encryption FC Blade
inserted in slot 12 of an HP DC SAN Backbone Director
and HP StorageWorks SAN Director 16-port 8Gb FC
Blades inserted in slots 1,2,7 on an HP DC04 SAN
Director.
Fixed in Fabric OS 7.1.0.DP Panic may occur with 3900 type printers when FICON
printer emulation is enabled.
Fixed in Fabric OS 7.1.0.The agshow command is missing from supportshow
and supportsave commands.
Fixed in Fabric OS 7.1.0.A stale AG entry may remain in the management server
database after the removal of AG.
Workaround prior to upgrade:The HP Encryption SAN Switch may be unable to connect
to any of the TKLMs.
Reboot the HP Encryption SAN Switch.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.The Nameserver is returning the wrong value for GFF_ID
(0x01F).
Fixed in Fabric OS 7.1.0.OUI information changed for a specific OEM.
Fixed in Fabric OS 7.1.0.In NPIV setup, perfttmon only displays ingress values
even when egress is selected.
Fixed in Fabric OS 7.1.0.Embedded platform with internal CU port connected to an
HBA turns into a G-Port.
Fixed in Fabric OS 7.1.0.During zone rename, when a new zone name is added in
the list and then removed, the old zone name causes a
switch panic.
Fixed in Fabric OS 7.1.0.Even thought static routes are not supported in Fabric
OS7.0, 'uRoute' commands are still present.
Fixed in Fabric OS 7.1.0.Starting with Fabric OS 6.3.x, there is unexpected NTP
behavior.
Fixed in Fabric OS 7.1.0.The CVLC daemon terminates as a result of processing
large encryption configuration (8K-9K Initiator Target
LUNs).
Fixed in Fabric OS 7.1.0.Users will get a FICON keepalive timeout on an HP 1606
SAN Extension Switch if there is not enough bandwidth
on the FCIP tunnel.
Workaround prior to upgrade:A switch upgrade from Fabric OS 6.3.x to 6.4.x in
IM2/IM3 mode causes zone daemon memory space
overrun.
Perform a HA Failover when the firmware is completely
upgraded.
Fixed in Fabric OS 7.1.0.
Workaround prior to upgrade:The WWN of an HBA connected to a switch running in
AG mode does not show up on the zoning admin windows.
Use CLI to manually configure zoning.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.After changing F-port buffers on an HP 1606 SAN
Extension Switch via WebTools, the switch cannot set
buffers back to the default setting of 8.
Fabric OS 7.1.0 fixes 27