HP B-series Fabric OS 7.1.0_blv Release Notes (5697-2827, September 2013)
Table 2 Fabric OS 7.1.0 closed defects (continued)
SolutionClosed defect summary
Fixed in Fabric OS 7.1.0.The CLI command portCfgFillWord (C, F, W in upper
case) command returns "exec error: 2, No such file or
directory".
Fixed in Fabric OS 7.1.0.Management ports go down after a code upgrade.
Fixed in Fabric OS 7.1.0.When trying to replicate only SNMP settings from one
switch to another switch using Network Advisor, AAA
settings are also being replaced.
Fixed in Fabric OS 7.1.0.F_Port trunk area configuration may be lost in switches
when upgrading to Fabric OS 6.4.x.
Workaround prior to upgrade:Users may not see the port/blade selection on the port
throughput, port error and blade aggregate throughput
graphs.
Users can manually enter the port number in the slot, port
format to display the desired graph. For blade aggregate
throughput, manually entering just the slot number will
display the appropriate graph.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.End to End (EE) monitor may behave unexpectedly when
configured on ports with no traffic.
Workaround prior to upgrade:The Encryption Engine does not send the
"Load,Unload;Load" SCSI command to the Virtual Initiator.
A host port toggle could be used to recover.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.The spinfab reports a failure on switches running Fabric
OS 6.4.x to switches with Fabric OS 6.2.x.
Workaround prior to upgrade:A fabric with ETIZoning, data stops flowing when switching
zoning enforcement from "Hard-Port" <--> "Hard-Wwn".
Users can toggle the port (disable/enable) to correct the
issue.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.An F-Port trunk loses connectivity after an HA Failover.
Workaround prior to upgrade:A disk Controller warm start processing causes multiple
IFCCs.
Disable emulation.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.While running diagnostics, an unsuccessful read at a low
level or bad SFP/media can trigger a switch panic.
Fixed in Fabric OS 7.1.0.In Web Tools, appropriate validation checking is missing,
which can lead to configuration missteps.
Fixed in Fabric OS 7.1.0.Fabric Watch messages report TX/RX values above 100%.
Fixed in Fabric OS 7.1.0.portloopbacktest options are not working properly
on 16 Gb/s blades.
Fixed in Fabric OS 7.1.0.After an HA Reboot on a Brocade 5460 switch, internal
ports go offline/online with warm recovery.
Workaround prior to upgrade:SRDF replication cannot handle busy response to
commands with FCIP FastWrite enabled.
Disable emulation.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.When a fabric rebuild and merge event occur close
together, the domain goes out of sync and the new device
will have the incorrect PID and be inaccessible to others.
Fabric OS 7.1.0 fixes 25