HP B-series Fabric OS 7.1.0_blv Release Notes (5697-2827, September 2013)
Table 2 Fabric OS 7.1.0 closed defects (continued)
SolutionClosed defect summary
Fixed in Fabric OS 7.1.0.Enabling track changes in native mode keeps the feature
active when AG mode is enabled but the CLI no longer
works.
Fixed in Fabric OS 7.1.0.The network scanning application causes high CPU
utilization by the CNM daemon.
Fixed in Fabric OS 7.1.0.In a FICON environment, XRC emulation sets the incorrect
sequence count and sequence ID on re-driven RRS Chain
after getting an immediate command retry status.
Workaround prior to upgrade:A switch Ethernet port sends frames with invalid MAC
addresses on the Brocade HP 8/8 e-port SAN Switch, HP
Use 100 Half duplex instead of Full Duplex mode.
8/40 SAN Switch, HP SN6000B 16Gb FC switch, and
the HP 1606 SAN Extension Switch.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.GA_NXT is not transferring the symbolic names (port or
node) from the non-local device table.
Fixed in Fabric OS 7.1.0.A Linux kernel module load bug causes a switch panic.
The sloterrshow and ptbufshow commands display
an invalid credit value for the longdistance link.
Fixed in Fabric OS 7.1.0.The sloterrshow and ptbufshow commands display
an invalid credit value for the longdistance link.
Fixed in Fabric OS 7.1.0.In a FICON environment, there are dropped frames during
a non-disruptive firmwaredownload with open systems
traffic.
Fixed in Fabric OS 7.1.0.The error message for a duplicate user assigned FAPWWN
will show the slot/port as -1/-1 if the port is in a different
logical switch.
Fixed in Fabric OS 7.1.0.The switch name is blanked out when FMS mode is enabled
for the first time.
Fixed in Fabric OS 7.1.0.The HP Encryption SAN switch does not perform a LOCATE
to the correct position after PI does a PLOGI/PRLI during
a restore.
Fixed in Fabric OS 7.1.0.Firmwaredownload fails on Co-CPU of a standby CP.
Fixed in Fabric OS 7.1.0.If a number of rwmonitors are created for a particular port
using the perfaddrwmonitor command and the monitors
are deleted, in some situations the perfcfgrestore
does not restore all of the monitors previously created.
Fixed in Fabric OS 7.1.0.During HA Failover, if there are too many timed-out and
un-routable frames being forwarded to the CPU, there is
potential for a port to lose credits.
Fixed in Fabric OS 7.1.0.A stuck VC detection is being intermittently delayed in the
bottleneck detection feature.
Fixed in Fabric OS 7.1.0.Commands continue running when telnet/SSH session ends
abruptly.
Fixed in Fabric OS 7.1.0.Software 'verify' error is detected when portstatsshow
is executed with an invalid index (999) and the -f option.
Fixed in Fabric OS 7.1.0.The security vulnerability check for CVE-2011-3192 fails
on switches running Fabric OS versions earlier than 7.0.2.
Fixed in Fabric OS 7.1.0.An F_Port is stuck in Disabled (N-Port Offline for F-Port)
after an AG reboot.
24