HP B-series Fabric OS 7.1.0_blv Release Notes (5697-2827, September 2013)

Table 2 Fabric OS 7.1.0 closed defects (continued)
SolutionClosed defect summary
Fixed in Fabric OS 7.1.0.The HP 8/40 SAN Switch panics if using 8G speed while
running portloopback with loopback cables.
Fixed in Fabric OS 7.1.0.Fabric Watch may not monitor every SNMP event.
Fixed in Fabric OS 7.1.0.Cleanup of crypto stat files fails due to low memory in error
scenarios such as rsync failures.
Fixed in Fabric OS 7.1.0.The HP Encryption SAN Switch does not support HBAs that
send ADISC request before PRLI request.
Fixed in Fabric OS 7.1.0.Manually stopping D-Port tests may result in a software
verify error. The configdownload command fails when
using a user account name with an underscore in it.
Fixed in Fabric OS 7.1.0.The diagshow command displays an incorrect speed value
for ports on FCOE10-24 blades.
Fixed in Fabric OS 7.1.0.Zone DB distribution fails to reach all domains in the fabric.
Fixed in Fabric OS 7.1.0.The SSHutil command fails for user names containing
upper case letters.
Workaround prior to upgrade:Ports on the 8 Gb/s switches running Fabric OS 7.0.0 or
later may negotiate to a 4 Gb/s speed even though the
link is capable of running at 8 Gb/s or higher.
Lock to a fixed speed.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.Unable to set the Timezone correctly on the systems of
countries that do not change time between standard and
daylight savings time.
Fixed in Fabric OS 7.1.0.Switches experience excessive CF usage due to generation
of the /var/log/ag_desc.txt.
Workaround prior to upgrade:There is an unsupported port speed configuration after
replacing an HP SN8000B 16Gb 32-port Fibre Channel
Manually correct the configured port speed and re-enable
the port.
Blade/HP SN8000B 16Gb 48-port Fibre Channel Blade
blade with an HP StorageWorks SAN Director 16-port
Fixed in Fabric OS 7.1.0.
8Gb FC Blade/ HP StorageWorks SAN Director 32-port
8Gb FC Blade/ HP StorageWorks SAN Director 48-port
8Gb FC Blade.
Fixed in Fabric OS 7.1.0.Hosts are unable to discover targets across the backbone
fabric with the HP 1606 SAN Extension Switch/ HP DC
SAN Director Multiprotocol Extension Blade in the
configuration.
Fixed in Fabric OS 7.1.0.Emulated FICON Tape Read Channel Program can grow
too large, resulting in FICON Protocol timeouts and aborts.
Fixed in Fabric OS 7.1.0.Enhanced SerDes tuning needed to address CRC with good
EOF errors.
Fixed in Fabric OS 7.1.0.A host is unable to Link up on an 8 Gb/s FC port when
the port is configured at a fixed speed of 4 Gb/s or 8
Gb/s.
Fixed in Fabric OS 7.1.0.A panic occurs in FCP Tape Emulation when retransmitting
previously sent partial frames because the gather buffer
count is too high.
Workaround prior to upgrade:FastWrite fails in a multi-hop VE-XISL configuration with
the HP 1606 SAN Extension Switch/ HP DC SAN Director
Multiprotocol Extension Blade in the configuration.
Disable FCIP Fastwrite and OSTP on the VE XISL.
Fixed in Fabric OS 7.1.0.
Fabric OS 7.1.0 fixes 23