HP B-series Fabric OS 7.1.0_blv Release Notes (5697-2827, September 2013)

Table 2 Fabric OS 7.1.0 closed defects (continued)
SolutionClosed defect summary
Fixed in Fabric OS 7.1.0.The severity level for SCN-1002 is set to "Error" instead
of "Warning".
Fixed in Fabric OS 7.1.0.Using Web Tools when attempting to upgrade a switch in
IM2/IM3 to Fabric OS 7.0, the fail message should direct
the user to the Interoperability tab to change the switch to
Brocade Native Fabric Mode, but does not.
Fixed in Fabric OS 7.1.0.IPv6(auto) address is not displayed on Web Tools if an
IPv4 address is not configured on a switch.
Fixed in Fabric OS 7.1.0.Replacing a failed HP DC SAN Director Multiprotocol
Extension Blade may result in one circuit on a crossport
configured tunnel getting stuck "In Progress...".
Fixed in Fabric OS 7.1.0.Fabricd crash encountered during D-port testing.
Fixed in Fabric OS 7.1.0.Caution message is displayed when executing D_Port CLI
mentions "only Brocade Branded SFPs", but should not.
Fixed in Fabric OS 7.1.0.The perfaddusermonitor/fmconfig are not correctly
detecting SOFf frame ingress/egress when filter monitor
is enabled.
Fixed in Fabric OS 7.1.0.IDLE not being sent after NOS - results in other issues and
eventually causes the port to become a G_Port.
Fixed in Fabric OS 7.1.0.Frame drops are observed after changing the FCR
backbone domain ID.
Fixed in Fabric OS 7.1.0.Access Gateway does not clean up frame exchange
properly if FLOGI/FDISC comes in from different ports
together with same exchange ID (OX-ID).
Fixed in Fabric OS 7.1.0.Firmware upgrades from Fabric OS 6.4 to 7.0 is blocked,
and the user does not get sufficient information from the
error message.
Workaround prior to upgrade:A kernel panic occurs following the insertion/removal of
SFPs on an HP 2408 FCoE Converged Network Switch.
Avoid reseating SFPs in a quick succession.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.Configdownload fails with specific timezones.
Fixed in Fabric OS 7.1.0.When Loop port (JBOD) and EX port are in the same chip
and LSAN is in place, Loop port drops the PLOGI accept
to the host and device discovery will fail.
Fixed in Fabric OS 7.1.0.During switch/blade initialization, the HP 1606 SAN
Extension Switch and the HP DC SAN Director
Multiprotocol Extension Blade forward BDPU broadcast
frames and users will see their Ethernet switch ports fenced
offline.
Fixed in Fabric OS 7.1.0.FICON XRC is suspended and LOGREC entries with
Command Rejects are displayed with the reason code
0x0F61 against a 0xFF command.
Fixed in Fabric OS 7.1.0.Users may notice excessive port errors (enc out) on HP 8/8
SAN Switch/ HP 8/24 SAN Switch ISL ports in a
configuration consisting of a mix of 4 Gb/s user ports
interconnected via 8 Gb/s ISLs.
Fixed in Fabric OS 7.1.0.A tape device connected to an HP Encryption SAN Switch
is dropping frames.
Fabric OS 7.1.0 fixes 19