HP B-series Fabric OS 7.1.0_blv Release Notes (5697-2827, September 2013)

Table 2 Fabric OS 7.1.0 closed defects (continued)
SolutionClosed defect summary
Fixed in Fabric OS 7.1.0.Unable to configure ports as extended distance using CLI
on the HP SN6000B 16Gb FC Switch 10G ports without
the Extended Fabric license. Users should be able to
configure any non-default Extended Fabric mode on a
licensed 10G FC port without requiring the Extended Fabric
license.
Workaround prior to upgrade:D-port tests fail on some ports when run on more than four
links simultaneously.
Toggle the port(s).
Fixed in Fabric OS 7.1.0.
Workaround prior to upgrade:Encrypted I/O halts when the initiator is configured for a
frame size of 512 kb.
Configure HBAs with 2112 frame size.
Fixed in Fabric OS 7.1.0.
Workaround prior to upgrade:There is a failed login attempt after a reboot from
firmwaredownload, causing a fwd panic.
Wait 1 minute after reboot before trying to log in.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.A Name Server assert triggered a switch panic.
Fixed in Fabric OS 7.1.0.In a FICON environment, the LPATH Reset flag is not
cleared on local paths if CUB is returned for the first init
IU after a reset - path cannot be assigned as CRP.
Workaround prior to upgrade:One of the E-ports connecting the HP 1606 SAN Extension
Switch and the HP 8/80 Base SAN Switch was segmented
due to (ESC mismatch, Enhanced TI Zone).
portdisable/enable will recover the port.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.Duplicate E_Port SCN from Port error messages are
displayed after an HA Failover.
Fixed in Fabric OS 7.1.0.Remote data replication application fails with multiple paths
(multiple port pairs between arrays) when FastWrite is
enabled on the FCIP tunnel.
Fixed in Fabric OS 7.1.0.A denial of service condition may occur with frequent HTTP
server restarts.
Fixed in Fabric OS 7.1.0.When XISL is disabled in VF, it results in a condition that
can trigger route problem. There may be a loss of
connectivity with large numbers of c3_other_discards.
Workaround prior to upgrade:Out of band bulk requests (SMI) may cause the Name
Server to panic in frame redirection environments.
Avoid GXX_ID (like GCS_ID) queries via out of band
(through RPC) querying with ID of device that is part of
frame redirection.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.FCoE LACP PDU length is non-standard and is discarded.
Fixed in Fabric OS 7.1.0.The RAS log Cx-5021 message for front port partial credit
loss on an EX-Port is not being received.
Fixed in Fabric OS 7.1.0.Unable to access the boot prom on a Brocade 8Gb SAN
Switch for HP BladeSystem c-Class when it is installed in
an embedded server chassis.
Workaround prior to upgrade:Failed tape jobs encountered with tape pipelining enabled
when utilizing a FICON to ESCON converter.
Disable tape pipelining.
Fixed in Fabric OS 7.1.0.
18