HP B-series Fabric OS 7.1.0_blv Release Notes (5697-2827, September 2013)

Table 2 Fabric OS 7.1.0 closed defects (continued)
SolutionClosed defect summary
Fixed in Fabric OS 7.1.0.There are delays detected in Name Server during FICON
CEC IMLs.
Fixed in Fabric OS 7.1.0.Web Tools zoning window fails to launch if device Port
WWN and Node WWN are the same.
Workaround prior to upgrade:FIPS mode with DSA keys are allowed, but should be a
blocked scenario.
CLI(s) to configure FIPS certified configuration for Mgmt IP
Sec, FCIP IP Sec, SSH public key authentication should be
executed for complete FIPS compliance.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.Unable to make modifications on the Canvas Configuration
List of WebTools (SID/DID Performance).
Fixed in Fabric OS 7.1.0.Continuous HA Failover on an HP DC SAN Backbone
Director may lead to an FFDC event.
Fixed in Fabric OS 7.1.0.A 4 Gb/s switch failed to go active due to ASIC
initialization failure.
Fixed in Fabric OS 7.1.0.After FCIP links in an FCR backbone fabric bounce several
times, FCR no longer translates all SID/DIDs properly.
Workaround prior to upgrade:DP panicked after modifying metric on FCIP Circuit using
a crossport with IPSec enabled.
Disable IPsec on the FCIP tunnel.
Fixed in Fabric OS 7.1.0.
Fixed in Fabric OS 7.1.0.In a FICON environment the active configuration is out of
synchronization with Fabric OS, indicating a port is
blocked after an HA Failover.
Fixed in Fabric OS 7.1.0.The HP Encryption SAN Switch is set to faulty, due to I/O
sizes greater than 512 KB starting at LBA 0 for an
encrypted LUN.
Fixed in Fabric OS 7.1.0.The portcfgshow command displays incorrect values
for "Fill Word (Current)" field.
Fixed in Fabric OS 7.1.0.TopTalker Monitor fails if user changes the monitor from
Egress to Ingress.
Fixed in Fabric OS 7.1.0.If users disable multiple circuits in an FCIP tunnel, traffic
may not be evenly distributed across remaining circuits.
Fixed in Fabric OS 7.1.0.There is a pdmd memory increase detected on the standby
CP of an HP SN8000B 8-Slot SAN Backbone Director with
max LS creation and fully populated EX-Ports after a long
period of time with I/O running.
Workaround prior to upgrade:FICON Tape Pipelining Channel aborts I/O after
presenting pending Attention status.
Disable FICON Tape pipelining.
Fixed in Fabric OS 7.1.0.
Workaround prior to upgrade:A port is segmented and the error “FABR-1001, 1 of 8”
trunks failed authentication during portenable of a port
range.
Disable and enable the segmented port.
Fixed in Fabric OS 7.1.0.
Workaround prior to upgrade:Access Gateway N-port is stuck in G-port after a firmware
upgrade with QoS enabled on the attached fabric switch.
Disable QoS on the Fabric switch for the impacted link.
Fixed in Fabric OS 7.1.0.
Fabric OS 7.1.0 fixes 17