HP B-series 16 Gb SAN Switch for HP BladeSystem c-Class installation instructions (5697-2589, September 2013)

Brocade 16Gb SAN Switch for
HP BladeSystem c-Class Quick
Start Instructions
© Copyright 2013 Hewlett-Packard Development Company, L.P.
Printed in the U.S.
*5697-2589*
HP Part Number: 5697-2589
Published: September 2013
Edition: 1
Overview
Read these instructions to install the Brocade 16Gb SAN
Switch in HP BladeSystem c-Class enclosures.
NOTE: The Brocade 16Gb SAN Switch refers
to Brocade Fibre Channel switch modules
compatible with the HP BladeSystem c-Class only.
Kit contents
The Brocade 16Gb SAN Switch kit contains:
Brocade 16 Gb SAN Switch for HP BladeSystem
c-Class Quick Start Instructions
One of the following switch models:
Brocade 16Gb/16-ports enabled SAN Switch
for HP BladeSystem c-Class
Brocade 16Gb/28-ports enabled SAN Switch
HP BladeSystem c-Class
Brocade 16Gb/28-ports enabled SAN Switch
Pwr Pk+ HP BladeSystem c-Class
HP Read Me First document
HP End User License Agreement letter
China ROHS substance table
Figure 1 Brocade 16Gb SAN Switch for HP BladeSystem
c-Class
2. External FC ports1. Midplane connector
4. Unit ID (UID), Health LED, and
Status LEDs
3. Installation handle
5. Reset button
Additional information
See the HP BladeSystem c-Class enclosure setup and
installation guide, provided with your enclosure, for
more information on the association between the server
mezzanine bays and the enclosure interconnect bays.
For example, where you install the mezzanine card
determines where you need to install the Brocade 16Gb
SAN Switch for HP BladeSystem c-Class.
For additional component information on other
interconnect modules, visit the following HP websites:
http://www.hp.com/go/bladesystem/interconnects
http://www.hp.com/go/bladesystem/documentation
16Gb SAN Switch connection identification
Figure 2 (page 1) shows the Brocade 16Gb SAN
Switch for HP BladeSystem c-Class external ports.
Figure 2 External ports
2. Trunk Group B1. Trunk Group A
3. User port number
NOTE: See the HP BladeSystem c-Class
enclosure setup and installation guide, provided
with your enclosure, for specific information on
BladeSystem c-Class enclosure internal port
mapping.
Install the 16Gb SAN Switch
For help identifying your specific enclosure setup and
available connections, see the HP BladeSystem c-Class
enclosure setup and installation guide, provided with
your enclosure, or the HP website HP website: http://
www.hp.com/go/bladesystem/documentation.
1. Locate the appropriate interconnect bay in the rear
of the enclosure.
CAUTION: Properly ground yourself before
handling the switch.
NOTE: Populate all enclosure interconnect
bays with an interconnect module or one of
the blank panels provided.
2. Press the handle latch to release the installation
handle.
Figure 3 Releasing the installation handle
2. Handle latch1. Installation handle latched
position
3. Installation handle released
NOTE: The Brocade 16Gb SAN Switch for
HP BladeSystem c-Class is a hot-pluggable
device. The enclosure power may be on or
off during install.
3. Align the Brocade 16Gb SAN Switch for HP
BladeSystem c-Class with the appropriate
interconnect bay according to your enclosure’s
specific configuration. Push firmly into the
interconnect bay.
Page 1