Fabric OS MIB Reference v6.4.0 (53-1001768-01, June 2010)
Fabric OS MIB Reference 123
53-1001768-01
entPhysicalEntry 1.3.6.1.2.1.47.1.1.1.1
4
FIGURE 37 entPhysicalTable containment hierarchy (entPhysicalContainsTable)
entPhysicalEntry 1.3.6.1.2.1.47.1.1.1.1
Information about a particular physical entity.
Brocade 7500 1 3 FRUs 2 PS 1 WWN unit
not a FRU
Brocade 7600 1 3 FRUs 2 PS 1 WWN unit
not a FRU
Brocade 12000 / 24000 10 blades 3 fans 4 PS 2 WWN units in 1
FRU
Brocade 48000 10 blades 3 fans 4 PS 2 WWN units in 1
FRU
Brocade DCX 8 blades 3 fans 4 PS 2 WWN units
Brocade DCX-4S 4 blades 2 fans 2 PS 1 WWN unit
Brocade Encryption Switch NA 3 fans 2 PS 1 WWN unit
Brocade 300 1 blade 3 fans 1 PS 1 WWN unit. Not a
FRU.
Brocade 5100 1 blade 2 fans 2 PS 1 WWN unit. Not a
FRU.
Brocade 5300 1 blade 3 fans 2 PS 1 WWN unit. Not a
FRU.
Brocade 8000 1 3 FRUs 2 PS 1 WWN unit
Brocade 7800 Extension
Switch
1 2 fans 2 PS 1 WWN unit
TABLE 12 entPhysicalTable entries for Brocade switches (Continued)
Platform Blades Fans Power supply WWN card
Chassis: one entry
Container: one entry for each FRU slot
Power supply
if the PS is not a FRU,
it will be directly
below the chassis
Module
if the Module is not
a FRU, it will be
directly below the
chassis
Fan
If the Fan is not a
FRU, it will be directly
below the chassis