Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)
Table Of Contents
- Contents
- About This Document
- Introduction To System Messages
- RASLog Messages
- AG System Messages
- AN System Messages
- AUTH System Messages
- ANV System Messages
- BKSW System Messages
- BL System Messages
- BLL System Messages
- BLS System Messages
- BM System Messages
- C2 System Messages
- CDR System Messages
- CEE CONFIG System Messages
- CER System Messages
- CHASSIS System Messages
- CNM System Messages
- CONF System Messages
- CTAP System Messages
- CVLC System Messages
- CVLM System Messages
- DAUTH System Messages
- EM System Messages
- ESS System Messages
- ESWCH System Messages
- EVMD System Messages
- FABR System Messages
- FABS System Messages
- FBC System Messages
- FCMC System Messages
- FCIP System Messages
- FCOE System Messages
- FCPD System Messages
- FCPH System Messages
- FCR System Messages
- FICON System Messages
- FICU System Messages
- FKLB System Messages
- FLOD System Messages
- FSPF System Messages
- FSS System Messages
- FSSM System Messages
- FW System Messages
- HAM System Messages
- HAMK System Messages
- HIL System Messages
- HLO System Messages
- HMON System Messages
- HSL System Messages
- HTTP System Messages
- IBD System Messages
- IBPD System Messages
- ICPD System Messages
- IPAD System Messages
- IPS System Messages
- ISCS System Messages
- ISNS System Messages
- KAC System Messages
- KSWD System Messages
- KTRC System Messages
- L2SYS System Messages
- LACP System Messages
- LANCE System Messages
- LFM System Messages
- LOG System Messages
- LSDB System Messages
- MFIC System Messages
- MPTH System Messages
- MQ System Messages
- MS System Messages
- MSTP System Messages
- NBFS System Messages
- NS System Messages
- NSM System Messages
- ONM System Messages
- PDM System Messages
- PDTR System Messages
- PLAT System Messages
- PMGR System Messages
- PORT System Messages
- PS System Messages
- PSWP System Messages
- RAS System Messages
- RCS System Messages
- RKD System Messages
- RMOND System Messages
- RPCD System Messages
- RTWR System Messages
- SAS System Messages
- SCN System Messages
- SEC System Messages
- SFLOW System Messages
- SNMP System Messages
- SPC System Messages
- SPM System Messages
- SS System Messages
- SSM System Messages
- SULB System Messages
- SWCH System Messages
- SYSC System Messages
- SYSM System Messages
- TAPE System Messages
- TRCE System Messages
- TRCK System Messages
- TS System Messages
- UCST System Messages
- UPTH System Messages
- WEBD System Messages
- XTUN System Messages
- ZEUS System Messages
- ZOLB System Messages
- ZONE System Messages
- Audit Log Messages
- AUDIT AG System Messages
- AUDIT AN System Messages
- AUDIT AUTH System Messages
- AUDIT BLS System Messages
- AUDIT CNM System Messages
- AUDIT CONF System Messages
- AUDIT CVLM System Messages
- AUDIT FCIP System Messages
- AUDIT FICU System Messages
- AUDIT FW System Messages
- AUDIT HTTP System Messages
- AUDIT IPAD System Messages
- AUDIT PORT System Messages
- AUDIT SEC System Messages
- AUDIT SNMP System Messages
- AUDIT SPM System Messages
- AUDIT SULB System Messages
- AUDIT SWCH System Messages
- AUDIT UCST System Messages
- AUDIT ZONE System Messages
342 Fabric OS Message Reference
53-1001767-01
FW-1428
42
FW-1428
Message <timestamp>, [FW-1428], <sequence-number>,, WARNING, <system-name>, Switch status
change contributing factor Power supply:
<Number Missing> absent.
Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of
missing power supplies is greater than or equal to the policy set by the switchStatusPolicySet
command.
Recommended
Action
Replace the missing power supply.
Severity WARNING
FW-1429
Message <timestamp>, [FW-1429], <sequence-number>,, WARNING, <system-name>, Switch status
change contributing factor: Power supplies are not redundant.
Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the power supplies
are not in the correct slots for redundancy.
Recommended
Action
Rearrange the power supplies so that one is in an odd slot and other in an even slot to make them
redundant.
Severity WARNING
FW-1430
Message <timestamp>, [FW-1430], <sequence-number>,, WARNING, <system-name>, Switch status
change contributing factor <string>.
Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of
faulty temperature sensors is greater than or equal to the policy set by the switchStatusPolicySet
command. A temperature sensor is faulty when the sensor value is not in the acceptable range or
is faulty.
Recommended
Action
Replace the field-replaceable unit (FRU) with the faulty temperature sensor.
Severity WARNING
FW-1431
Message <timestamp>, [FW-1431], <sequence-number>,, WARNING, <system-name>, Switch status
change contributing factor Fan:
<Number Bad> bad.
Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of
faulty fans is greater than or equal to the policy set by the switchStatusPolicySet command. A fan is
faulty when sensor value is not in the acceptable range or is faulty.