Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)
Table Of Contents
- Contents
- About This Document
- Introduction To System Messages
- RASLog Messages
- AG System Messages
- AN System Messages
- AUTH System Messages
- ANV System Messages
- BKSW System Messages
- BL System Messages
- BLL System Messages
- BLS System Messages
- BM System Messages
- C2 System Messages
- CDR System Messages
- CEE CONFIG System Messages
- CER System Messages
- CHASSIS System Messages
- CNM System Messages
- CONF System Messages
- CTAP System Messages
- CVLC System Messages
- CVLM System Messages
- DAUTH System Messages
- EM System Messages
- ESS System Messages
- ESWCH System Messages
- EVMD System Messages
- FABR System Messages
- FABS System Messages
- FBC System Messages
- FCMC System Messages
- FCIP System Messages
- FCOE System Messages
- FCPD System Messages
- FCPH System Messages
- FCR System Messages
- FICON System Messages
- FICU System Messages
- FKLB System Messages
- FLOD System Messages
- FSPF System Messages
- FSS System Messages
- FSSM System Messages
- FW System Messages
- HAM System Messages
- HAMK System Messages
- HIL System Messages
- HLO System Messages
- HMON System Messages
- HSL System Messages
- HTTP System Messages
- IBD System Messages
- IBPD System Messages
- ICPD System Messages
- IPAD System Messages
- IPS System Messages
- ISCS System Messages
- ISNS System Messages
- KAC System Messages
- KSWD System Messages
- KTRC System Messages
- L2SYS System Messages
- LACP System Messages
- LANCE System Messages
- LFM System Messages
- LOG System Messages
- LSDB System Messages
- MFIC System Messages
- MPTH System Messages
- MQ System Messages
- MS System Messages
- MSTP System Messages
- NBFS System Messages
- NS System Messages
- NSM System Messages
- ONM System Messages
- PDM System Messages
- PDTR System Messages
- PLAT System Messages
- PMGR System Messages
- PORT System Messages
- PS System Messages
- PSWP System Messages
- RAS System Messages
- RCS System Messages
- RKD System Messages
- RMOND System Messages
- RPCD System Messages
- RTWR System Messages
- SAS System Messages
- SCN System Messages
- SEC System Messages
- SFLOW System Messages
- SNMP System Messages
- SPC System Messages
- SPM System Messages
- SS System Messages
- SSM System Messages
- SULB System Messages
- SWCH System Messages
- SYSC System Messages
- SYSM System Messages
- TAPE System Messages
- TRCE System Messages
- TRCK System Messages
- TS System Messages
- UCST System Messages
- UPTH System Messages
- WEBD System Messages
- XTUN System Messages
- ZEUS System Messages
- ZOLB System Messages
- ZONE System Messages
- Audit Log Messages
- AUDIT AG System Messages
- AUDIT AN System Messages
- AUDIT AUTH System Messages
- AUDIT BLS System Messages
- AUDIT CNM System Messages
- AUDIT CONF System Messages
- AUDIT CVLM System Messages
- AUDIT FCIP System Messages
- AUDIT FICU System Messages
- AUDIT FW System Messages
- AUDIT HTTP System Messages
- AUDIT IPAD System Messages
- AUDIT PORT System Messages
- AUDIT SEC System Messages
- AUDIT SNMP System Messages
- AUDIT SPM System Messages
- AUDIT SULB System Messages
- AUDIT SWCH System Messages
- AUDIT UCST System Messages
- AUDIT ZONE System Messages

Fabric OS Message Reference 225
53-1001767-01
FCR-1038
34
FCR-1038
Message <timestamp>, [FCR-1038], <sequence-number>,, WARNING, <system-name>, Total zone
entries exceeded local fabric limits by <overflow> entries, in zone: <zone name>,
zone limit: <LSAN zone limit>.
Probable Cause Indicates that the number of cfg/zone/alias entries created in a local fabric is greater than the
local switch&apos zone database limitations.
Recommended
Action
Remove excess cfg/zone/alias entries so that the number of logical storage area network (LSAN)
zones created is within the range of the local database limitations.
Severity WARNING
FCR-1039
Message <timestamp>, [FCR-1039], <sequence-number>,, INFO, <system-name>, Local LSAN zone
<zone name> device entries for backbone LSAN exhausted.
Probable Cause Indicates that the number of devices in the specified logical storage area network (LSAN) defined in
the backbone fabric is greater than allowed by the local LSAN zone database limitations.
Recommended
Action
Remove excess device entries from this LSAN zone until the number of devices is within the range
of the local LSAN zone database limitations.
Severity INFO
FCR-1040
Message <timestamp>, [FCR-1040], <sequence-number>,, INFO, <system-name>, Proxy device
deleted in the backbone fabric.
Probable Cause Indicates that a proxy device created in the backbone fabric was deleted.
Recommended
Action
No action is required.
Severity INFO
FCR-1041
Message <timestamp>, [FCR-1041], <sequence-number>,, INFO, <system-name>, LSAN zone
device removed in the backbone fabric.
Probable Cause Indicates that a logical storage area network (LSAN) zone device within the backbone fabric was
removed.
Recommended
Action
No action is required.