Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)
Table Of Contents
- Contents
- About This Document
- Introduction To System Messages
- RASLog Messages
- AG System Messages
- AN System Messages
- AUTH System Messages
- ANV System Messages
- BKSW System Messages
- BL System Messages
- BLL System Messages
- BLS System Messages
- BM System Messages
- C2 System Messages
- CDR System Messages
- CEE CONFIG System Messages
- CER System Messages
- CHASSIS System Messages
- CNM System Messages
- CONF System Messages
- CTAP System Messages
- CVLC System Messages
- CVLM System Messages
- DAUTH System Messages
- EM System Messages
- ESS System Messages
- ESWCH System Messages
- EVMD System Messages
- FABR System Messages
- FABS System Messages
- FBC System Messages
- FCMC System Messages
- FCIP System Messages
- FCOE System Messages
- FCPD System Messages
- FCPH System Messages
- FCR System Messages
- FICON System Messages
- FICU System Messages
- FKLB System Messages
- FLOD System Messages
- FSPF System Messages
- FSS System Messages
- FSSM System Messages
- FW System Messages
- HAM System Messages
- HAMK System Messages
- HIL System Messages
- HLO System Messages
- HMON System Messages
- HSL System Messages
- HTTP System Messages
- IBD System Messages
- IBPD System Messages
- ICPD System Messages
- IPAD System Messages
- IPS System Messages
- ISCS System Messages
- ISNS System Messages
- KAC System Messages
- KSWD System Messages
- KTRC System Messages
- L2SYS System Messages
- LACP System Messages
- LANCE System Messages
- LFM System Messages
- LOG System Messages
- LSDB System Messages
- MFIC System Messages
- MPTH System Messages
- MQ System Messages
- MS System Messages
- MSTP System Messages
- NBFS System Messages
- NS System Messages
- NSM System Messages
- ONM System Messages
- PDM System Messages
- PDTR System Messages
- PLAT System Messages
- PMGR System Messages
- PORT System Messages
- PS System Messages
- PSWP System Messages
- RAS System Messages
- RCS System Messages
- RKD System Messages
- RMOND System Messages
- RPCD System Messages
- RTWR System Messages
- SAS System Messages
- SCN System Messages
- SEC System Messages
- SFLOW System Messages
- SNMP System Messages
- SPC System Messages
- SPM System Messages
- SS System Messages
- SSM System Messages
- SULB System Messages
- SWCH System Messages
- SYSC System Messages
- SYSM System Messages
- TAPE System Messages
- TRCE System Messages
- TRCK System Messages
- TS System Messages
- UCST System Messages
- UPTH System Messages
- WEBD System Messages
- XTUN System Messages
- ZEUS System Messages
- ZOLB System Messages
- ZONE System Messages
- Audit Log Messages
- AUDIT AG System Messages
- AUDIT AN System Messages
- AUDIT AUTH System Messages
- AUDIT BLS System Messages
- AUDIT CNM System Messages
- AUDIT CONF System Messages
- AUDIT CVLM System Messages
- AUDIT FCIP System Messages
- AUDIT FICU System Messages
- AUDIT FW System Messages
- AUDIT HTTP System Messages
- AUDIT IPAD System Messages
- AUDIT PORT System Messages
- AUDIT SEC System Messages
- AUDIT SNMP System Messages
- AUDIT SPM System Messages
- AUDIT SULB System Messages
- AUDIT SWCH System Messages
- AUDIT UCST System Messages
- AUDIT ZONE System Messages

Fabric OS Message Reference 179
53-1001767-01
FABR-1013
26
FABR-1013
Message <timestamp>, [FABR-1013], <sequence-number>, FFDC, CRITICAL, <system-name>, No
Memory: pid=<fabric process id> file=<source file name> line=<line number within
the source file>.
Probable Cause Indicates that there is not enough memory in the switch for the fabric module to allocate. This
message is rare and usually indicates a problem with the Fabric OS.
Recommended
Action
The system will recover by failing over to the standby CP.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity CRITICAL
FABR-1014
Message <timestamp>, [FABR-1014], <sequence-number>, FFDC, ERROR, <system-name>, Port
<port number> Disabled: Insistent Domain ID <Domain ID> could not be obtained.
Principal Assigned Domain ID = <Domain ID>
Probable Cause Indicates that the specified port received an request domain ID (RDI) accept message containing a
principal-switch-assigned domain ID that is different from the insistent domain ID (IDID). Fibre
connectivity (FICON) mode requires an insistent domain ID. If an RDI response has a different
domain ID, then the port is disabled.
Recommended
Action
Run the configShow command to view the fabric.ididmode. A ‘0’ means the IDID mode is disabled;
a ‘1’ means it is enabled.
Set the switch to insistent domain ID mode. This mode is set under the configure command or in
Web Tools on the Switch Admin > Configure window.
Severity ERROR
FABR-1015
Message <timestamp>, [FABR-1015], <sequence-number>, FFDC, ERROR, <system-name>, FICON
Insistent DID max retry exceeded: All E-Ports will be disabled. Switch is
isolated.
Probable Cause Indicates that the application exceeded request domain ID (RDI) requests for the insistent domain
ID. All E_Ports are disabled, isolating the specified switch from the fabric.
Recommended
Action
Verify that the insistent domain ID is unique in the fabric and then re-enable the E_Ports. Run the
fabricShow command to view the domain IDs across the fabric and the configure command to
change the insistent domain ID mode. Refer to the Fabric OS Command Reference for more
information on these commands.
Severity ERROR