Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)
Table Of Contents
- Contents
- About This Document
- Introduction To System Messages
- RASLog Messages
- AG System Messages
- AN System Messages
- AUTH System Messages
- ANV System Messages
- BKSW System Messages
- BL System Messages
- BLL System Messages
- BLS System Messages
- BM System Messages
- C2 System Messages
- CDR System Messages
- CEE CONFIG System Messages
- CER System Messages
- CHASSIS System Messages
- CNM System Messages
- CONF System Messages
- CTAP System Messages
- CVLC System Messages
- CVLM System Messages
- DAUTH System Messages
- EM System Messages
- ESS System Messages
- ESWCH System Messages
- EVMD System Messages
- FABR System Messages
- FABS System Messages
- FBC System Messages
- FCMC System Messages
- FCIP System Messages
- FCOE System Messages
- FCPD System Messages
- FCPH System Messages
- FCR System Messages
- FICON System Messages
- FICU System Messages
- FKLB System Messages
- FLOD System Messages
- FSPF System Messages
- FSS System Messages
- FSSM System Messages
- FW System Messages
- HAM System Messages
- HAMK System Messages
- HIL System Messages
- HLO System Messages
- HMON System Messages
- HSL System Messages
- HTTP System Messages
- IBD System Messages
- IBPD System Messages
- ICPD System Messages
- IPAD System Messages
- IPS System Messages
- ISCS System Messages
- ISNS System Messages
- KAC System Messages
- KSWD System Messages
- KTRC System Messages
- L2SYS System Messages
- LACP System Messages
- LANCE System Messages
- LFM System Messages
- LOG System Messages
- LSDB System Messages
- MFIC System Messages
- MPTH System Messages
- MQ System Messages
- MS System Messages
- MSTP System Messages
- NBFS System Messages
- NS System Messages
- NSM System Messages
- ONM System Messages
- PDM System Messages
- PDTR System Messages
- PLAT System Messages
- PMGR System Messages
- PORT System Messages
- PS System Messages
- PSWP System Messages
- RAS System Messages
- RCS System Messages
- RKD System Messages
- RMOND System Messages
- RPCD System Messages
- RTWR System Messages
- SAS System Messages
- SCN System Messages
- SEC System Messages
- SFLOW System Messages
- SNMP System Messages
- SPC System Messages
- SPM System Messages
- SS System Messages
- SSM System Messages
- SULB System Messages
- SWCH System Messages
- SYSC System Messages
- SYSM System Messages
- TAPE System Messages
- TRCE System Messages
- TRCK System Messages
- TS System Messages
- UCST System Messages
- UPTH System Messages
- WEBD System Messages
- XTUN System Messages
- ZEUS System Messages
- ZOLB System Messages
- ZONE System Messages
- Audit Log Messages
- AUDIT AG System Messages
- AUDIT AN System Messages
- AUDIT AUTH System Messages
- AUDIT BLS System Messages
- AUDIT CNM System Messages
- AUDIT CONF System Messages
- AUDIT CVLM System Messages
- AUDIT FCIP System Messages
- AUDIT FICU System Messages
- AUDIT FW System Messages
- AUDIT HTTP System Messages
- AUDIT IPAD System Messages
- AUDIT PORT System Messages
- AUDIT SEC System Messages
- AUDIT SNMP System Messages
- AUDIT SPM System Messages
- AUDIT SULB System Messages
- AUDIT SWCH System Messages
- AUDIT UCST System Messages
- AUDIT ZONE System Messages

162 Fabric OS Message Reference
53-1001767-01
EM-1051
22
EM-1051
Message <timestamp>, [EM-1051], <sequence-number>,, INFO, <system-name>, <FRU Id>:
Inconsistency detected, FRU re-initialized.
Probable Cause Indicates that an inconsistent state was found in the field-replaceable unit (FRU). This occurs if the
state of the FRU was changing during a failover. The FRU is reinitialized and traffic might have been
disrupted.
Recommended
Action
No action is required.
Severity INFO
EM-1057
Message <timestamp>, [EM-1057], <sequence-number>,, WARNING, <system-name>, Blade:<Slot
Id> is getting reset:<Fault reason>.
Probable Cause Indicates the blade is being automatically reset because of known resetable transient errors such
as an application-specific integrated circuit (ASIC) parity error.
Recommended
Action
No action is required if the switch does not reach the reset threshold for the switch or blade. If the
reset threshold is reached on the switch or blade, the switch or blade will be faulted and should be
replaced.
Severity WARNING
EM-1058
Message <timestamp>, [EM-1058], <sequence-number>,, WARNING, <system-name>, Switch gets
reset:
<Fault reason>
Probable Cause Indicates the switch is being automatically reset because of a known resetable transient problem
such as an application-specific integrated circuit (ASIC) parity error.
Recommended
Action
No action is required if the switch does not reach the reset threshold for the switch or blade. If the
reset threshold is reached on the switch or blade, the switch or blade will be faulted and should be
replaced.
Severity WARNING
EM-1059
Message <timestamp>, [EM-1059], <sequence-number>, FFDC, ERROR, <system-name>, <Slot
number or Switch> with id <FRU Id> cannot be found in the fru description xml
file.
Probable Cause Indicates that a blade inserted in the specified slot or the switch (for nonbladed switches) is not
compatible with the switch configuration software. The system may not be usable.