Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)
Table Of Contents
- Contents
- About This Document
- Introduction To System Messages
- RASLog Messages
- AG System Messages
- AN System Messages
- AUTH System Messages
- ANV System Messages
- BKSW System Messages
- BL System Messages
- BLL System Messages
- BLS System Messages
- BM System Messages
- C2 System Messages
- CDR System Messages
- CEE CONFIG System Messages
- CER System Messages
- CHASSIS System Messages
- CNM System Messages
- CONF System Messages
- CTAP System Messages
- CVLC System Messages
- CVLM System Messages
- DAUTH System Messages
- EM System Messages
- ESS System Messages
- ESWCH System Messages
- EVMD System Messages
- FABR System Messages
- FABS System Messages
- FBC System Messages
- FCMC System Messages
- FCIP System Messages
- FCOE System Messages
- FCPD System Messages
- FCPH System Messages
- FCR System Messages
- FICON System Messages
- FICU System Messages
- FKLB System Messages
- FLOD System Messages
- FSPF System Messages
- FSS System Messages
- FSSM System Messages
- FW System Messages
- HAM System Messages
- HAMK System Messages
- HIL System Messages
- HLO System Messages
- HMON System Messages
- HSL System Messages
- HTTP System Messages
- IBD System Messages
- IBPD System Messages
- ICPD System Messages
- IPAD System Messages
- IPS System Messages
- ISCS System Messages
- ISNS System Messages
- KAC System Messages
- KSWD System Messages
- KTRC System Messages
- L2SYS System Messages
- LACP System Messages
- LANCE System Messages
- LFM System Messages
- LOG System Messages
- LSDB System Messages
- MFIC System Messages
- MPTH System Messages
- MQ System Messages
- MS System Messages
- MSTP System Messages
- NBFS System Messages
- NS System Messages
- NSM System Messages
- ONM System Messages
- PDM System Messages
- PDTR System Messages
- PLAT System Messages
- PMGR System Messages
- PORT System Messages
- PS System Messages
- PSWP System Messages
- RAS System Messages
- RCS System Messages
- RKD System Messages
- RMOND System Messages
- RPCD System Messages
- RTWR System Messages
- SAS System Messages
- SCN System Messages
- SEC System Messages
- SFLOW System Messages
- SNMP System Messages
- SPC System Messages
- SPM System Messages
- SS System Messages
- SSM System Messages
- SULB System Messages
- SWCH System Messages
- SYSC System Messages
- SYSM System Messages
- TAPE System Messages
- TRCE System Messages
- TRCK System Messages
- TS System Messages
- UCST System Messages
- UPTH System Messages
- WEBD System Messages
- XTUN System Messages
- ZEUS System Messages
- ZOLB System Messages
- ZONE System Messages
- Audit Log Messages
- AUDIT AG System Messages
- AUDIT AN System Messages
- AUDIT AUTH System Messages
- AUDIT BLS System Messages
- AUDIT CNM System Messages
- AUDIT CONF System Messages
- AUDIT CVLM System Messages
- AUDIT FCIP System Messages
- AUDIT FICU System Messages
- AUDIT FW System Messages
- AUDIT HTTP System Messages
- AUDIT IPAD System Messages
- AUDIT PORT System Messages
- AUDIT SEC System Messages
- AUDIT SNMP System Messages
- AUDIT SPM System Messages
- AUDIT SULB System Messages
- AUDIT SWCH System Messages
- AUDIT UCST System Messages
- AUDIT ZONE System Messages
Fabric OS Message Reference 151
53-1001767-01
EM-1006
22
EM-1006
Message <timestamp>, [EM-1006], <sequence-number>, FFDC, CRITICAL, <system-name>, <FRU
Id>
has faulted. Sensors below minimum limits.
Probable Cause Indicates that the sensors show the voltage is below minimum limits. The switch or specified blade
is being shut down for environmental reasons; the voltage is too low.
Recommended
Action
If this problem occurs on a blade, it usually indicates a hardware problem on the blade; replace the
blade.
If this problem occurs on a switch, it usually indicates a hardware problem on the main board;
replace the switch.
Severity CRITICAL
EM-1007
Message <timestamp>, [EM-1007], <sequence-number>, FFDC, CRITICAL, <system-name>, <FRU
Id>
is being reset. Sensors has exceeded max limits.
Probable Cause Indicates that the voltage on a switch has exceeded environmental limits. A reset is sent to the
faulty slot or the switch for nonbladed switches.
Recommended
Action
There is most likely a voltage hardware problem on the blade or motherboard of the switch.
For the Brocade DCX, 24000 and 48000, replace the blade field-replaceable unit (FRU).
For the Brocade 3900 replace the motherboard FRU.
For the Brocade 200E, 3016, 3250, 3850, 4012, 4016, 4018, 4020, 4024, 4100, 4900, 5000,
7500, AP7600, replace the switch.
Severity CRITICAL
EM-1008
Message <timestamp>, [EM-1008], <sequence-number>, FFDC, CRITICAL, <system-name>, Unit in
<Slot number or Switch> with ID <FRU Id> is faulted, it is incompatible with the
<type of incompatibility> configuration.
Probable Cause Indicates that a blade inserted in the specified slot or the switch (for nonbladed switches) is not
compatible with either the platform configuration or the logical switch configuration. The blade is
faulted.
Recommended
Action
If the blade is not compatible, replace the blade and ensure the replacement blade is compatible
with your control processor (CP) type. If the incompatibility is with the logical switch configuration,
change the configuration with the lscfg command to be consistent with the blade type or remove
the blade.
Severity CRITICAL