Brocade Fabric OS v7.2.0d Release Notes v1.0
Fabric OS v7.2.0d Release Notes v1.0 Page 20 of 52
users with versions prior to v12.1.4 and Oracle JRE 1.7.0 update 45 will not be able to launch WebTools
from Network Advisor.
FOS v7.2.0d is qualified and supported with Oracle JRE 1.7.0 update 25, update 45, and update 51. Users
will not see a warning message when WebTools is launched through HTTPS with JRE 1.7.0 update 25 or
update 45. Launching WebTools through Brocade Network Advisor is also supported with JRE 1.7.0 update
25 and update 45. Launching WebTools with Oracle JRE 1.7.0 update 51 through Brocade Network
Advisor is only supported on version 12.1.5 or later. With JRE 1.7.0 update 51, users could see some
browser warning messages that can be ignored.
SMI Compatibility
It is important to note that host SMI-S agents cannot be used to manage switches running FOS v7.2.
If users want to manage a switch running FOS v7.2 using SMI-S interface, they must use Brocade
Network Advisor’s integrated SMI agent.
Fabric OS Compatibility
The following table lists the earliest versions of Brocade software supported in this release, that is, the earliest
supported software versions that interoperate. Brocade recommends using the latest software versions to get
the greatest benefit from the SAN.
To ensure that a configuration is fully supported, always check the appropriate SAN, storage or blade server
product support page to verify support of specific code levels on specific switch platforms prior to installing on
your switch. Use only FOS versions that are supported by the provider.
For a list of the effective end-of-life dates for all versions of Fabric OS, visit the following Brocade Web site:
http://www.brocade.com/support/end_of_life.jsp
Supported Products and FOS Interoperability
4900, 7500, 7500e, 5000, 200E, 48K
Brocade 4012, 4016, 4018, 4020, 4024, 4424
v6.2.2 or later
6
Brocade 5410, 5480, 5424, 5450, 5460, 5470, NC-5480
v6.2.0 or later
6
Brocade DCX, 300, 5100, 5300
v6.1.0e and later
2 6 8
VA-40FC
v6.2.1_vfc
6
, v6.2.2 or later
6
Brocade DCX-4S
v6.2.0 or later
6 8
Brocade DCX with FS8-18 blade(s), Brocade Encryption Switch
v6.1.1_enc or later
6
Brocade 7800, DCX and DCX-4S with FCOE10-24 or FX8-24 blades
V6.3.0 or later
Brocade 8000
9
V6.1.2_CEE1 or later
Brocade DCX/DCX-4S with FA4-18 blade(s)
DCX requires v6.0.x or later
6
, DCX-4S
requires 6.2.x or later
5 6
Brocade DCX 8510-8/DCX 8510-4
FOS v7.0 or later
Brocade 6510
FOS v7.0 or later
Brocade 6505
FOS v7.0.1 or later