Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April 2009)

32 Fabric OS Message Reference
53-1001157-01
AG-1027
2
Probable Cause Indicates there are insufficient resources.
Recommended
Action
Run configure CLI on AG switch and increase the number of allowed logins on this port.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity WARNING
AG-1027
Message <timestamp>, [AG-1027], <sequence-number>,, WARNING, <system-name>, Unable to
handle this login request on port <port> because NPIV capability is not enabled on
this port.
Probable Cause Indicates NPIV is not enabled.
Recommended
Action
Run portcfgnpivport CLI on the AG switch and enable the NPIV capability on this port.
Severity WARNING
AG-1028
Message <timestamp>, [AG-1028], <sequence-number>,, WARNING, <system-name>, Device with
Port WWN <port_name> tried to perform fabric login through port <fport>, without
having access permission.
Probable Cause Indicates the device does not have login access for that port, as per ADS policy set by the user.
Recommended
Action
Add the device in to the ADS allow list for that port using ag --adsadd command.
Severity WARNING
AG-1029
Message <timestamp>, [AG-1029], <sequence-number>,, INFO, <system-name>, F_Port to N_Port
mapping has been updated for N_Port <n_port>.
Probable Cause Indicates that the F_Ports mapped to an N_Port have changed and the config file has been
updated.
Recommended
Action
No action is required.
Severity INFO