Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April 2009)
Fabric OS Message Reference 591
53-1001157-01
SULB-1031
100
Recommended
Action
The firmwareDownload command will continue after the switch has rebooted. Run the
firmwareDownloadStatus command to monitor progress. If the problem persists, contact your
switch service provider.
Severity WARNING
SULB-1031
Message AUDIT, <timestamp>, [SULB-1032], WARNING, FIRMWARE, <event-initiator-details>,
<event-location>, , Relocating an internal firmware image on the CP.
Probable Cause Indicates the switch has rebooted with the new firmware and is relocating the AP firmware.
Recommended
Action
Wait for the operation to complete.
Severity WARNING
SULB-1032
Message AUDIT, <timestamp>, [SULB-1032], WARNING, FIRMWARE, <event-initiator-details>,
<event-location>, , Relocating an internal firmware image on the CP.
Probable Cause Indicates the switch has started firmware download to the co-CPU.
Recommended
Action
Wait for the operation to complete.
Severity WARNING
SULB-1033
Message AUDIT, <timestamp>, [SULB-1033], WARNING, FIRMWARE, <event-initiator-details>,
<event-location>, , Switch has completed relocating the internal firmware image.
Probable Cause Indicates the firmwareDownload process has completed normally on the switch.
Recommended
Action
Run the firmwareShow command to verify the firmware versions. Run the switchShow command to
make sure the switch is enabled.
Severity WARNING
SULB-1034
Message AUDIT, <timestamp>, [SULB-1034], ERROR, FIRMWARE, <event-initiator-details>,
<event-location>, , Firmwaredownload timed out.
Probable Cause Indicates there may be an error caused by a switch initialization issue after the internal image is
relocated. It may also be caused by an internal Ethernet issue or by persistent storage failure.