Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April 2009)
Fabric OS Message Reference 461
53-1001157-01
SEC-1326
75
Recommended
Action
No action is required unless the switch must remain in the fabric. If the switch must remain in the
fabric, add the switch world wide name (WWN) to the SCC policy, then attempt to join the switch
with the fabric.
Severity ERROR
SEC-1326
Message <timestamp>, [SEC-1326], <sequence-number>,, INFO, <system-name>, Event: fddcfg
--fabwideset, Status: success, Info: Fabric wide configuration set to <Fabric-wide
configuration set by user>.
Probable Cause Indicates the specified event has occurred.
Recommended
Action
Verify the event was planned. If the event was planned, no action is required. If the event was not
planned, take appropriate action as defined by your enterprise security policy.
Severity INFO
SEC-1327
Message <timestamp>, [SEC-1327], <sequence-number>,, WARNING, <system-name>, Strict
<Policy Name> policy is conflicting with domain <Domain Number>
Probable Cause Indicates the policy is conflicting with the domain.
Recommended
Action
No action is required. The domain is denied by disallowing all its E_ports connected to the fabric. If
the domain should be allowed to merge with the fabric, then resolve the issue by making the
conflicting policies the same.
Severity WARNING
SEC-1328
Message <timestamp>, [SEC-1328], <sequence-number>,, ERROR, <system-name>, Attempt to
enable secure mode failed. Reason: <Reason>.
Probable Cause Indicates the secModeEnable command failed on the fabric because Authentication Policy is
enabled on the switch.
Recommended
Action
Verify the security event was planned. If the security event was planned, run the authUtil --policy
passive command to disable the Authentication Policy and retry the secModeEnable command.
Severity ERROR