Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April 2009)
Fabric OS Message Reference 453
53-1001157-01
SEC-1250
75
Severity INFO
SEC-1250
Message <timestamp>, [SEC-1250], <sequence-number>,, WARNING, <system-name>, DCC
enforcement API failed: <failed action> err=<status>, key=<data>
Probable Cause Indicates an internal error caused the DCC policy enforcement to fail.
Recommended
Action
Retry the failed security command.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity WARNING
SEC-1251
Message <timestamp>, [SEC-1251], <sequence-number>,, ERROR, <system-name>, Policy to
binary conversion error: <text message> <value>.
Probable Cause Indicates the security database conversion failed because of invalid values. The reason is specified
in the text message variable and a faulty value is printed in the value variable.
Recommended
Action
Retry the failed security command.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity ERROR
SEC-1253
Message <timestamp>, [SEC-1253], <sequence-number>,, ERROR, <system-name>, Bad DCC
interface state during <Phase>, state=<state>.
Probable Cause Indicates an internal error has caused the device connection control (DCC) policy update to fail in
the provision, commit, or cancel phases.
Recommended
Action
Retry the failed security command.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity ERROR
SEC-1300
Message <timestamp>, [SEC-1300], <sequence-number>,, INFO, <system-name>, This switch is
in VcEncode mode. Security is not supported.