Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April 2009)

442 Fabric OS Message Reference
53-1001157-01
SEC-1159
75
SEC-1159
Message <timestamp>, [SEC-1159], <sequence-number>,, INFO, <system-name>, Non_Reachable
domain <Domain ID>.
Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only
occur when the primary fabric configuration server (FCS) is distributing the security database to the
other switches in the fabric and local validation finds that there is an error in the security database.
This is a rare occurrence.
Recommended
Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.
Severity INFO
SEC-1160
Message <timestamp>, [SEC-1160], <sequence-number>,, INFO, <system-name>, Duplicate port
<port ID> in port list (<port list>).
Probable Cause Indicates a duplicate port member exists in the specified port list.
Recommended
Action
Verify that there is no duplicate member in the port list.
Severity INFO
SEC-1163
Message <timestamp>, [SEC-1163], <sequence-number>,, ERROR, <system-name>, System is
already in secure mode. Lockdown option cannot be applied.
Probable Cause Indicates the lockdown option was attempted while the fabric is already in secure mode.
Recommended
Action
Do not use lockdown option with the secModeEnable command when a switch is already in secure
mode.
Severity ERROR
SEC-1164
Message <timestamp>, [SEC-1164], <sequence-number>,, ERROR, <system-name>, Lockdown
option cannot be applied on a non-FCS switch.
Probable Cause Indicates the attempt to enable security is made on a switch that is not present in the fabric
configuration server (FCS) list.
Recommended
Action
Add the switch to the FCS policy list when using the lockdown option to enable security.