Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April 2009)

430 Fabric OS Message Reference
53-1001157-01
SEC-1097
75
Severity ERROR
SEC-1097
Message <timestamp>, [SEC-1097], <sequence-number>,, ERROR, <system-name>, Cannot find
<active or defined> policy set.
Probable Cause Indicates the specified policy could not be found.
Recommended
Action
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity ERROR
SEC-1098
Message <timestamp>, [SEC-1098], <sequence-number>,, ERROR, <system-name>, No <active or
defined> FCS list.
Probable Cause Indicates the specified policy could not be found.
Recommended
Action
Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command
and contact your switch service provider.
Severity ERROR
SEC-1099
Message <timestamp>, [SEC-1099], <sequence-number>,, ERROR, <system-name>, Please enable
your switch before running secModeEnable.
Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only
occur when the primary fabric configuration server (FCS) is distributing the security database to the
other switches in the fabric and local validation finds that there is an error in the security database.
This is a rare occurrence.
Recommended
Action
Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.
Severity ERROR
SEC-1100
Message <timestamp>, [SEC-1100], <sequence-number>,, ERROR, <system-name>, FCS switch
present. Command terminated.