SEC-1034
75
Probable Cause Indicates a member parameter in the secPolicyAdd command is invalid (e. g., it may include an
invalid character, such as an asterisk). A valid switch identifier (a WWN, a domain ID, or a switch
name) must be provided as a member parameter in the secPolicyAdd command. Only the
secPolicyCreate command supports use of the asterisk for adding switches to policies.
Recommended
Action
Run the secPolicyAdd command using a valid switch identifier (WWN, domain ID, or switch name)
to add specific switches to the switch connection control (SCC) policy.
Refer to the Fabric OS Command Reference for more information on the secPolicyAdd and
secPolicyCreate commands.
Severity ERROR
SEC-1034
Message <timestamp>, [SEC-1034], <sequence-number>,, ERROR, <system-name>, Invalid member
<policy member>.
Probable Cause Indicates the input list has an invalid member.
Recommended
Action
Verify the member names, and input the correct information.
Severity ERROR
SEC-1035
Message <timestamp>, [SEC-1035], <sequence-number>,, ERROR, <system-name>, Invalid device
WWN
<device WWN>.
Probable Cause Indicates the specified world wide name (WWN) is invalid.
Recommended
Action
Enter the correct WWN value.
Severity ERROR
SEC-1036
Message <timestamp>, [SEC-1036], <sequence-number>,, ERROR, <system-name>, Device name
<device name> is invalid due to a missing colon.
Probable Cause Indicates one or more device names mentioned in the securePolicyCreate or securePolicyAdd
command does not have the colon character (:) as required.
Recommended
Action
Run the secPolicyCreate or secPolicyAdd command with a properly formatted device name
parameter.
Severity ERROR