Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April 2009)
388 Fabric OS Message Reference
53-1001157-01
PS-1004
66
Probable Cause Indicates that the restoring configuration has attempted to set the end-to-end monitoring mask on
at least one ISL port.
Recommended
Action
No action is required. End-to-end monitoring is not supported on ISL ports when ISL monitoring is
enabled. ISL monitoring can only be disabled through the Fabric Access API.
Severity WARNING
PS-1004
Message <timestamp>, [PS-1004], <sequence-number>,, WARNING, <system-name>, Failed to add
end-to-end monitors on port
<port> which is an ISL port.
Probable Cause Indicates that the restoring configuration has attempted to add end-to-end monitors on at least one
ISL port.
Recommended
Action
No action is required. End-to-end monitoring is not supported on ISL ports when ISL monitoring is
enabled. ISL monitoring can only be disabled through the Fabric Access API.
Severity WARNING
PS-1005
Message <timestamp>, [PS-1005], <sequence-number>,, WARNING, <system-name>, ISL monitor
on port
<port> stopped counting because no hardware resources are available
Probable Cause Indicates that ISL and end-to-end monitors have used up all hardware resources.
Recommended
Action
To resume counting, delete some end-to-end monitors sharing the same hardware resource pool.
Severity WARNING
PS-1006
Message <timestamp>, [PS-1006], <sequence-number>,, WARNING, <system-name>, Failed to add
fabricmode toptalker monitors on domain=<domain id>, because end-to-end monitors
are configured on this switch.
Probable Cause Indicates that end-to-end monitors are configured on the switch.
Recommended
Action
Delete end-to-end monitors on that switch and re-install fabricmode TopTalker monitor. End-to-end
monitors and fabricmode toptalker monitors are mutually exclusive.
Severity WARNING