Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April 2009)

374 Fabric OS Message Reference
53-1001157-01
PDM-1022
61
Probable Cause Indicates a system call failed.
Recommended
Action
Run the firmwareDownload command to reinstall the firmware.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity WARNING
PDM-1022
Message <timestamp>, [PDM-1022], <sequence-number>,, WARNING, <system-name>, The switch
is configured only with IPv6.
Probable Cause Indicates the parity data manager (PDM) cannot synchronize with its peer because the firmware
does not support IPv6.
Recommended
Action
Configure the local switch with IPv4 addresses.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity WARNING
PDM-1023
Message <timestamp>, [PDM-1023], <sequence-number>,, WARNING, <system-name>, Radius is
configured for IPv6.
Probable Cause Indicates the parity data manager (PDM) cannot synchronize with its peer because the Radius
server is configured for IPv6 addresses. IPv6 is not supported by older firmware.
Recommended
Action
Configure the Radius server with IPv4 addresses.
Severity WARNING
PDM-1024
Message <timestamp>, [PDM-1021], <sequence-number>,, WARNING, <system-name>, DNS is
configured for IPv6.
Probable Cause Indicates the parity data manager (PDM) cannot synchronize with its peer because the domain
name service (DNS) is configured for IPv6. IPv6 is not supported by older firmware.
Recommended
Action
Run the firmwareDownload command to reinstall the firmware.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity WARNING