HIL-1601
38
HIL-1601
Message <timestamp>, [HIL-1601], <sequence-number>,, ERROR, <system-name>, Using backup
temperature sensor. Service immediately.
Probable Cause Indicates that temperature readings from the primary sensor are out of range.
Recommended
Action
Run the fanShow command to verify that all fans are operating correctly. Replace any deteriorating
fan field-replaceable units (FRUs).
Run the tempShow command to verify temperature values. If any sensor is too high, monitor the
switch. Try rebooting or power cycling the switch.
Severity ERROR
HIL-1602
Message <timestamp>, [HIL-1602], <sequence-number>, FFDC, CRITICAL, <system-name>,
Multiple temperature sensors failed. Service immediately.
Probable Cause Indicates that temperature readings from multiple sensors are out of range.
Recommended
Action
Run the fanShow command to verify that all fans are operating correctly. Replace any deteriorating
fan field-replaceable units (FRUs).
Run the tempShow command to verify temperature values. If any sensor is too high, monitor the
switch. Try rebooting or power cycling the switch.
Severity CRITICAL
HIL-1603
Message <timestamp>, [HIL-1603], <sequence-number>, FFDC, CRITICAL, <system-name>,
<failure count> fans out of service. System is shutting down immediately.
Probable Cause Indicates that the total fan failure count is greater than or equal to two.
Recommended
Action
To avoid causing damage to the switch, the system shuts down automatically. To help prevent
future problems, make sure that all the fans are working properly.
Severity CRITICAL
HIL-1610
Message <timestamp>, [HIL-1610], <sequence-number>, FFDC, WARNING, <system-name>, Fan/PS
unit <Combo fan/power supply unit number> not supplying power, fan speeds not
available. Please ensure that the unit has power and the switch is on.
Probable Cause Indicates that the power supply is not connected to a power source or it is not switched on or the
unit is faulty. Applicable only to Brocade 5100.