Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April 2009)
298 Fabric OS Message Reference
53-1001157-01
HAM-1005
36
• Fastboot
• Giveup Master:SYSM
• CP Faulty:SYSM
• FirmwareDownload
• ConfigDownload:MS
• ChangeWWN:EM
• Reboot:WebTool
• Fastboot:WebTool
• Software Fault:Software Watchdog
• Software Fault:Kernel Panic
• Software Fault:ASSERT
• Reboot:SNMP
• Fastboot:SNMP
• Reboot
• Chassis Config
• Reboot:API
• Reboot:HAM
• EMFault:EM
Recommended
Action
Check the error log on both CPs for additional messages that might indicate the reason for the
reboot.
Severity INFO
HAM-1005
Message <timestamp>, [HAM-1005], <sequence-number>,, INFO, <system-name>, HeartBeat Miss
reached threshold.
Probable Cause Indicates that either the active control processor (CP) EMAC controller or the standby CP is down.
The active CP will run a diagnostic test on the EMAC controller and will wait for the standby CP to
reset it if it is down.
Recommended
Action
No action is required.
Severity INFO
HAM-1006
Message <timestamp>, [HAM-1006], <sequence-number>,, CRITICAL, <system-name>,EMAC
controller for Active CP is BAD.
Probable Cause Indicates that the local EMAC controller on the active control processor (CP) is BAD as determined
by the diagnostic test run by the HAM module.