Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April 2009)

Fabric OS Message Reference 203
53-1001157-01
FICN-1080
28
Recommended
Action
No action is required.
Severity INFO
FICN-1080
Message <timestamp>, [FICN-1080], <sequence-number>,, INFO, <system-name>,
DevTapeEgr:ReadCpReport:Path=<FICON PATH>:Emuls=0x<the number of idle state to
non-idle state transitions while this tape was loaded>:Cmds=0x<the number of
emulated host read commands processed while this tape was loaded>:Chains=0x<the
number of emulated host chains processed while this tape was loaded>:MBytes=<the
number of emulated read Kilobytes processed while this tape was loaded>.
Probable Cause Indicates a Rewind and Unload IO has been processed from a remotely connected LPAR and Read
Channel Program pipelining was performed on the currently loaded tape.
Recommended
Action
No action is required.
Severity INFO
FICN-1081
Message <timestamp>, [FICN-1081], <sequence-number>,, WARNING, <system-name>,
DevTapeIng:LRJ received on Path=<FICON PATH> lastCmds=0x<Last 4 commands received
from the channel for this device> lastStatus=0x<Last 4 status values presented to
the channel for this device> treating as system reset event.
Probable Cause Indicates an LRJ from a FICON channel indicates that the channel does not have a path established
to the CU.
Recommended
Action
This is normally an unexpected event, contact your vendor's customer support for assistance.
Severity WARNING
FICN-1082
Message <timestamp>, [FICN-1082], <sequence-number>,, WARNING, <system-name>,
EmulEls:CSWR_RSCN received on GEPort=<GEPortNumber> VEPort=<VEPortNumber>
Domain=0x<Domain Port Host> Port=0x<Device Side>.
Probable Cause Indicates an attached port which had a FICON emulated path established has logged out from the
switch.
Recommended
Action
This may be an unexpected event, contact your vendor's customer support for assistance.
Severity WARNING