Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April 2009)

Fabric OS Message Reference 139
53-1001157-01
FABR-1046
20
Recommended
Action
Make sure that all the switches in the fabric have the same Base Switch attribute or disable VF
mode for the conflicting switch using the fosconfig command.
Severity ERROR
FABR-1046
Message <timestamp>, [FABR-1046], <sequence-number>, ERROR, <system-name>, Detected Base
Switch conflict with neighbor switch <Switchname> (domain <Domain ID>), BS <Base
Switch Mode>. E-ports (<Number of E-ports disabled>) connected to the switch are
disabled.
Probable Cause Indicates that the remote switch has a Base Switch attribute conflict with the local switch. All the
E_ports directly connected to the conflicting switch are disabled.
Recommended
Action
Make sure that all the switches in the fabric have the same Base Switch attribute or upgrade the
switch firmware to a VF-capable firmware.
Severity ERROR