Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April 2009)

Fabric OS Message Reference 121
53-1001157-01
EM-1068
17
EM-1068
Message <timestamp>, [EM-1068], <sequence-number>,, ERROR, <system-name>, High
Availability Service Management subsystem failed to respond. A required component
is not operating.
Probable Cause Indicates that the HA subsystem has not returned a response within four minutes of the request
from the Environmental Manager. It usually indicates that some component has not started
properly or has terminated. The specific component that has failed might be indicated in other
messages or debug data. There are serious internal Fabric OS configuration or hardware problems
on the switch.
Recommended
Action
Reboot or power cycle the switch. If the message persists, collect switch information using the
supportsave command, and contact your switch service provider.
Severity ERROR
EM-1069
Message <timestamp>, [EM-1069], <sequence-number>,, INFO, <system-name>, Slot <FRU slot
number> is being powered off.
Probable Cause Indicates a blade is being intentionally powered off.
Recommended
Action
No action is required.
Severity INFO
EM-1070
Message <timestamp>, [EM-1070], <sequence-number>,, INFO, <system-name>, Slot <FRU slot
number> is being powered on.
Probable Cause Indicates a blade is being intentionally powered on.
Recommended
Action
No action is required.
Severity INFO
EM-2003
Message <timestamp>, [EM-2003], <sequence-number>,, ERROR, <system-name>, <Slot Id or
Switch for pizza boxes> has failed the POST tests. FRU is being faulted.
Probable Cause Indicates that a field-replaceable unit (FRU) has failed the Power-On Self-Test. Refer to the
/tmp/post[1/2].slot#.log file for more information on faults. To view this log file you must be logged
in at the root level. The ID will be Switch for non-bladed systems.