Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April 2009)
98 Fabric OS Message Reference
53-1001157-01
CVLC-1013
15
Recommended
Action
Use cryptocfg command to change the LUN's metadata mode.
Severity ERROR
CVLC-1013
Message <timestamp>, [CVLC-1013], <sequence-number>,, ERROR, <system-name>, Unable to
retrieve key record from the key archive.\nContainer: <Target container name>,
Initiator: <Initiator physical WWN>, LUN ID: <LUN ID>.
Probable Cause Indicates that the encryption engine is unable to retrieve the key record base on the key ID found in
the metadata.
Recommended
Action
No action is required.
Severity ERROR
CVLC-1014
Message <timestamp>, [CVLC-1014], <sequence-number>,, ERROR, <system-name>, Missing Key
ID from user input.\nContainer: <Target container name>, Initiator: <Initiator
physical WWN>, LUN ID: <LUN ID>.
Probable Cause Indicates that the data state in the LUN configuration is in the Encrypted state without a key ID and
there is no metadata found on the LUN.
Recommended
Action
Use cryptocfg command to add the key ID, if available.
Severity ERROR
CVLC-1015
Message <timestamp>, [CVLC-1015], <sequence-number>,, ERROR, <system-name>, LUN is set to
read only mode. Reason: <Reason for LUN is set to read only mode>.\nContainer:
<Target container name>, Initiator: <Initiator physical WWN>, LUN ID: <LUN ID>.
Probable Cause Indicates that the LUN is set as read only because there is a conflict in the configuration.
Recommended
Action
No action is required.
Severity ERROR