Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April 2009)
Fabric OS Message Reference 77
53-1001157-01
Chapter
11
CHASSIS System Messages
CHASSIS-1002
Message <timestamp>, [CHASSIS-1002], <sequence-number>,, ERROR, <system-name>,
ki_gd_register_action failed with rc =<ret val>.
Probable Cause Indicates an internal error.
Recommended
Action
For a bladed system, run the slotPowerOff command and slotPowerOn command on the blade to
recover the system. For a non-bladed system, run the fastBoot command on the switch to recover
the system.
Severity ERROR
CHASSIS-1003
Message <timestamp>, [CHASSIS-1003], <sequence-number>,, ERROR, <system-name>, Slot
ENABLED but Not Ready during recovery, disabling slot = <slot number> rval =
<return value>.
Probable Cause Indicates that the slot state has been detected as inconsistent during failover or recovery.
Recommended
Action
On a Brocade 24000 or 48000 switch, run the slotPowerOff command followed by the slotPowerOn
command. On a Brocade 7500 or AP7600 switch, reboot or power cycle the switch.
Severity ERROR
CHASSIS-1004
Message <timestamp>, [CHASSIS-1004], <sequence-number>,, ERROR, <system-name>, Blade
attach failed during recovery, disabling slot = <slot number>, rval = <return
value>.
Probable Cause Indicates that a blade has failed during failover or recovery.
Recommended
Action
On a Brocade 24000 or 48000 switch, run the slotPowerOff command followed by the slotPowerOn
command. On a Brocade 200E, 3250, 3850, 3900, 4012, 4016, 4018, 4020, 4024, 4100, 4900,
5000, 7500, or AP7600 switch, reboot or power cycle the switch.
Severity ERROR