Brocade Fabric OS Message Reference guide v6.2.0 (53-1001157-01, April 2009)

68 Fabric OS Message Reference
53-1001157-01
BM-1053
7
Recommended
Action
The blade ports are cleared automatically. No action is required.
Severity INFO
BM-1053
Message <timestamp>, [BM-1053], <sequence-number>,, WARNING, <system-name>, Failed to
establish connection between CP and Application Processor. Faulting switch.
Probable Cause Indicates the control processor (CP) could not establish a connection to the application processor
to communicate.
Recommended
Action
On the Brocade 7500 or 7600, switch off and on all primary power to power-cycle the unit.
Severity WARNING
BM-1054
Message <timestamp>, [BM-1054], <sequence-number>,, INFO, <system-name>, AP firmware
<Blade firmware> is not consistent with system firmware <System firmware>.
Auto-leveling AP firmware to match system firmware.
Probable Cause Indicates the policy of the specified blade is set to auto-level the blade firmware to the system
firmware. This may be due to one of the following reasons:
Blade firmware was detected to be different from CP firmware due to a firmware upgrade
The blade was just inserted and had a different firmware loaded
Recommended
Action
No action is required. The blade will automatically download the updated firmware.
Severity INFO
BM-1055
Message <timestamp>, [BM-1055], <sequence-number>,, WARNING, <system-name>,
Firmwaredownload timed-out for AP. Faulting switch.
Probable Cause Indicates the firmwareDownload command on the application processor (AP) blade failed.
Recommended
Action
Use the slotPowerOff and slotPowerOn commands or reseat the affected blade. On the Brocade
DCX, 7500 or 7600, switch off and on all primary power in order to power-cycle the unit.
Severity WARNING